background image

OPERATING INSTRUCTIONS 

 

 

Page 12 

www.schroff.biz

 

 

 

 

Accessories 

(optional)

 

Mating connector / intermediate plate 3 U for one PSU 

Order No.: 23098 – 105 

Mating connector / intermediate plate 3 U for two PSUs horizontally 

Order No.: 23098 – 115

 

Mating connector / intermediate plate 6 U for one PSU 

Order No.: 23098 – 116

 

Mating connector / intermediate plate 6 U for two PSUs vertical 

Order No.: 23098 – 117

 

 

Caution & Notes 

CAUTION 

These component level power supplies are intended exclusively for installation within other equipment 
by an industrial assembly operation or by professional installers. These are Class I power supplies; the 
ground pin of input connector J1 must be properly connected to earth ground in end use. Component 
power supplies are to be installed in end-use equipment according to the requirements of the safety 
standard used for that equipment. These power supplies are not designed to be operated outside of an 
enclosure which provides a means of mechanical, electrical, and fire protection. To maintain SELV 
requirements, the outputs should not be connected together in any manner which causes the total 
output voltage to exceed 60 VDC. 

PROTECTIVE EARTHING 

The Power Supply must be properly grounded to mains protective earthing termination at end use. 

FUSING 

In case of failure, the Power Supply must be returned to a Schroff Authorized Service Center. There 
are no user-serviceable parts in the Power Supply. 

LIMITED WARRANTY 

Schroff warrants each power supply of its manufacture for a period of two (2) years from the date of 
original shipment. This warranty applies to defects in materials and workmanship that result in non-
performance to published specifications.  
 
Schroff assumes no liabilities for consequential damages of any kind through the use or misuse of its 
products by any user. No other obligations are expressed or implied. 
 
Please note that the specifications, terms, and conditions stated are subject to change without notice. 
 
 
 
 

SCHROFF GmbH 
Langenalber Strasse 96 – 100 
 
D – 75334 Straubenhardt 
 
 
Phone:  +49 7082 794 – 0 
Fax:  

+49 7082 794 – 200   

Web: 

www.schroff.biz

 

Содержание maxpowerPRO CPA Series

Страница 1: ...ries are highly reliable power supplies for CompactPCI systems which are increasingly used in communications industrial military aerospace and other applications These power supplies offer high power...

Страница 2: ...uption of Vi without affecting the outputs Input Transient Protection A metal oxide VDR Voltage Dependent Resistor together with the input fuse form an effective protection against high input voltage...

Страница 3: ...A dIo1 dt 2 A s Vo2 Io2 10 A dIo2 dt 2 A s 120 120 mV td regulatio n Recovery time 100 100 s Vo Temperature coefficient of output voltage TC min TC max 0 Io nom Vi min Vi max 0 3 0 2 mV K Output Vo3...

Страница 4: ...10 A dIo2 dt 2 A s 150 150 mV td regulation Recovery time 300 300 s Vo Temperature coefficient of output voltage TC min TC max 0 Io nom Vi min Vi max 0 3 0 2 mV K Output Vo3 12 V Vo4 12 V Unit Charact...

Страница 5: ...rature TA max see Temperatures the temperature measured at the measurement point of the case temperature TC see Mechanical Data will approach after an initial warm up phase the indicated maximum value...

Страница 6: ...f logic signals or to enable the source to start up before full load is applied Note If this function is not used the inhibit pin 39 can be left open circuit not connected If pin 39 is connected to a...

Страница 7: ...A250 up to Version V115 is not monitored Vi min of CPA models is considered as insufficient when vi remains for typ 30 ms below 2 Vi min Connector pin 42 signal VFAL is internally connected via the dr...

Страница 8: ...g terminals causes the converters to share the output current evenly In n 1 redundant systems a failure of a single converter will not lead to a system failure since the outputs are already decoupled...

Страница 9: ...following specifications Electromagnetic Immunity Immunity type tests Electromagnetic Emission Radiated and conducted emissions comply with EN 55011 55022 class A In addition CPA500 550 meet conducted...

Страница 10: ...ations valid for an air pressure of 800 1200 hPa 800 1200 mbar Reliability MTBF Ratings at specified case temperature Model Ground benign 40 C Ground fixed 40 C 70 C Ground mobile 50 C Unit MTBF acc t...

Страница 11: ...nected 33 M V2SENSE V2 Remote Sense 34 M S RTN Sense Return 35 M V1SHARE V1 Current Share 36 M V3SENSE V3 Remote Sense 37 M Reserved 3 38 M DEG Degrade Signal 39 M INH Inhibit 40 M Reserved 3 41 M V2S...

Страница 12: ...vides a means of mechanical electrical and fire protection To maintain SELV requirements the outputs should not be connected together in any manner which causes the total output voltage to exceed 60 V...

Отзывы: