KL 1500 HAL / KL 1500 H - Operating instructions

 

 

  

9/15 

Select the submenu "On/Off" to enable the operating hour counter. Turn the light intensity setting 
rotary dial (4) to select "On" and confirm your selection with a brief press of the rotary dial (a 
checkmark will appear in the menu field). Select "Menu" followed by "Exit". The lamp will switch 
back on. The operating hours are indicated at the top left of the LCD display (5). 

To turn off the operating hour indicator, select "On/Off" in the submenu. Turn the light intensity 
setting rotary dial (4) to select "Off" and confirm your selection with a brief press of the rotary dial (a 
checkmark will appear in the menu field). Select "Menu" followed by "Exit". 

If using the operating hour indicator of the lamp, you should reset the operating hour counter to 0 h 
after changing the lamp. This will not happen automatically! Press and hold the light intensity setting 
rotary dial (4) > 5 seconds to access the menu control. Next, select the "Reset" submenu. Turn the 
light intensity setting rotary dial (4) to select "Reset" and confirm your selection with a brief press of 
the rotary dial (a checkmark will appear in the menu field). Select "Menu" followed by "Exit". The 
counting of the lamp's operating hours in the memory will start anew (beginning with 0h) regardless 
of whether the operating hour indicator is turned or turned off. 

 

 
2.6  Supplementary optics 

 

 

 

The use of the supplementary optics ensures that you will achieve uniform, high intensity 
illumination even when using light guides with a smaller bundle diameter than 9 mm. 

If the illumination is carried out with imaging or focussing optical systems at the light guide exit, 
perfectly uniform illumination is achieved by moving the supplementary optics out of the optical path. 

To pivot the supplementary optics in and out, turn the pivot lever (6) clockwise or anti-clockwise to 
the corresponding symbols. The supplementary optics always need to be pivot in or out as far as 
they will go! 

 
 

 

Содержание KL 1500 H

Страница 1: ...User Manual Distribution in the UK Ireland Lambda Photometrics Limited Lambda House Batford Mill Harpenden Herts AL5 5BZ United Kingdom E info lambdaphoto co uk W www lambdaphoto co uk T 44 0 1582 764...

Страница 2: ...erating instructions 1 15 Operating instructions KL 1500 HAL KL 1500 H Status March 2016 different name KL1500H possible In this operating instructions for the sake of simplicity only the KL 1500 HAL...

Страница 3: ...ion 6 2 1 Light guide connection 6 2 2 Power connection 6 2 3 Start up procedure 7 2 4 Light intensity setting 7 2 5 LCD display indication and settings 8 2 6 Supplementary optics 9 2 7 Filter slide 1...

Страница 4: ...lectronic light intensity setting 2 4 5 LCD display 2 5 6 Pivot lever for supplementary optics 2 6 7 Filter slide 2 7 8 Carrying handle 1 9 Lamp compartment with halogen cold light reflector lamp 3 10...

Страница 5: ...n g incident l ials To av following ins Operating n ger caution surface rce is intend he intensive d out High guides standard th ght source ive and full co uirements o AN CSA C2 ese instruc ve the ope...

Страница 6: ...ace f before bein eveloped fo sed in explo power suppl be opened d out by th r of the syst e for damage instructio er of fire guide exit w ammable lig appropriate level in ord all light g ance at even...

Страница 7: ...with a s ring prolong commende ng sign has ipped in ad mp unless from being mistake befo m the light g e light guide the light inte e in the ligh e error mes rd of type signated pl The instrum 100 24...

Страница 8: ...our temperature Kelvin at the light guide exit by means of a single press on the brightness control 4 Please note that this indicator is not an exact physical quantity and therefore subject to a certa...

Страница 9: ...in per cent or Kelvin see Point 2 4 You can toggle the display by briefly pressing the light intensity setting rotary dial 4 once Indicator of lamp operating time You can have the LCD display 5 indic...

Страница 10: ...sity setting rotary dial 4 5 seconds to access the menu control Next select the Reset submenu Turn the light intensity setting rotary dial 4 to select Reset and confirm your selection with a brief pre...

Страница 11: ...r slide 7 the filter sl the filter slid has cooled of this nece e 7 from th lint free glo e filter is the ket left to t source for a his position instructio which can lide must a de in an int d down...

Страница 12: ...t 6 4 into th the screws back on and Operating nd lamp so to remin ce is switch to the devic by pressin t will go Mo off the sock r Point 6 4 de the lamp on the light guaranteed cements start by ca sc...

Страница 13: ...d faults are commonly displayed on the LCD display 5 see Point 2 5 Overheating Insufficient cooling temperature monitor has triggered Open Circuit Lamp circuit interrupted lamp defective or missing No...

Страница 14: ...ange of accessories is available for your KL 1500 HAL A separate brochure gives you comprehensive information turn to page 15 for the order address Only SCHOTT light guides and accessories guarantee p...

Страница 15: ...t kg approx 4 2 Cooling Axial fan Ambient temperature C 5 40 Relative humidity at 31 C ambient temperature 85 31 C to 40 C ambient temperature linearly decreasing to 75 Air pressure hPa 800 1060 Trans...

Страница 16: ...t and t ymbol means th posed of separa eached their en TT AG Lighting m that customers e make use of th elping preserve ore information o chott com lightin Operating dle diameter mm values lm lm lm an...

Страница 17: ...ited Kingdom E info lambdaphoto co uk W www lambdaphoto co uk T 44 0 1582 764334 F 44 0 1582 712084 Distribution in the UK Ireland Lambda Photometrics Limited Lambda House Batford Mill Harpenden Herts...

Отзывы: