- 4 -
Turn-On, Sensitivity and Volume Settings
Set the On-Off/Sensitivity Control to position 2 and adjust the Volume Control until the idling
tone reaches a desired level. The sensitivity of the unit can be increased (to detect smaller
objects at greater depth) or decreased (to detect larger objects at smaller depths) by adjusting
the On-Off/Sensitivity Control. Setting the Sensitivity Control to position 2 provides what is
referred to as the “Normal Operating Range.” Positions 3 to 5 increase the sensitivity; position 1
decreases the sensitivity.
The locator can be oriented in any direction without producing a significant change in the
frequency of the tone from its idling frequency.
When using headphones, the Volume Control has no impact on the output level of the audio
signal.
Figure 2: Sensitivity Set for Normal Range (position 2)
Search Procedure
Turn the instrument on, set the sensitivity control to position 2
(Normal Range), and grasp the locator as illustrated in Figure 3.
Because the upper sensor is located near where the locator is
usually held, wrist watches may produce unwanted changes in
the tone’s frequency. Remove your wrist watch or hold the
locator in the other hand. Keep the locator away from your
shoes since they may contain magnetic material.
To obtain the maximum area of coverage, the locator should be
swept from side-to-side. When the locator comes within range
of an object, you will hear an increase in the frequency of the
output signal.
Figure 3: Searching with the Locator