 Before operating your new appliance please read this

instruction booklet carefully. It contains important
information for safe use, installation and care of the
appliance.

!

 Please keep these operating instructions for future

reference. Pass them on to possible new owners of the
appliance.

!

 Intensive and prolonged use may require additional

ventilation, for example, opening a window or
ventilation more efficient by increasing the suction
power
The appliance has the following technical
specifications:

Category: II 2H3+

Positioning

!

 Keep packaging material out of the reach of children. It

can become a choking or suffocation hazard (see
Precautions and tips).

!

 The appliance must be installed by a qualified

professional according to the instructions provided.
Incorrect installation may cause harm to people and
animals or may damage property.

!

 This unit may be installed and used only in permanently

ventilated rooms in accordance with British Standard
Codes Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S.
6891 Current Editions. The following requirements must be
observed:
• The room must be equipped with an air extraction

system that expels any combustion fumes. This may
consist of a hood or an electric fan that automatically
starts each time the appliance is switched on.

• The room must also allow proper air circulation, as air is

needed for combustion to occur normally. The flow of
air must not be less than 2 m3/h per kW of installed
power.

The air circulation system may
take air directly from the outside
by means of a pipe with an inner
cross section of  at least 100
cm2; the opening must not be
vulnerable to any type of
blockages.

The system can also provide the
air needed for combustion
indirectly, i.e. from adjacent
rooms fitted with air circulation
tubes as described above.
However, these rooms must not
be communal rooms, bedrooms
or rooms that may present a fire
hazard.

• Liquid petroleum gas sinks to the floor as it is heavier

than air. Therefore, rooms containing LPG cylinders
must also be equipped with vents to allow gas to
escape in the event of a leak. As a result LPG
cylinders, whether partially or completely full, must not
be installed or stored in rooms or storage areas that are
below ground level (cellars, etc.). It is advisable to
keep only the cylinder being used in the room,
positioned so that it is not subject to heat produced by
external sources (ovens, fireplaces, stoves, etc. ) which
could raise the temperature of the cylinder above 50°C.

Fitting the appliance

Gas and mixed hobs are manufactured with type X
degree protection against overheating. The following
precautions must be taken when installing the hob:
• Kitchen cabinets adjacent to the appliance and taller

than the top of the hob must be at least 50 mm from
the edge of the hob.

• Hoods must be installed according to their relative

installation instruction manuals and at a minimum
distance of 700 mm from the hob.

• Place the wall cabinets
adjacent to the hood at a
minimum height of 540 mm from
the hob (see figure).
If the hob is installed beneath a
wall cabinet, the latter must be
situated at a minimum of 700 mm
above the hob (see figure).

Installation

Make sure you take all the necessary precautions to guarantee
proper installation in compliance with the applicable norms in
force regarding accident-prevention for electrical connection.
For the correct operation of the appliance when built into the
cabinet, it is vital that the minimum distances illustrated in Fig. 1
be respected. The hob features a type Y degree of protection
against overheating in compliance with norms. All surfaces
adjacent to the cabinet and the back panel should be made of
materials resistant to a temperature of 65°C.

Installation

Enlarging the ventilation slot
between window and floor.

Adjacent
Room

Room to be
Vented

A

Examples of ventilation holes
for comburant air.

In a chimney stack or branched flue. 
(exclusively for cooking appliances)

Directly to 
the Outside

600mm min.

540mm min.

700mm min.

Содержание SH09PGWAX

Страница 1: ...er and nozzle specifications Description of the appliance 8 Overall view Start up and use 9 10 Practical advice on using the burners Precautions and tips 11 General safety Disposal Maintenance and car...

Страница 2: ...d Liquid petroleum gas sinks to the floor as it is heavier than air Therefore rooms containing LPG cylinders must also be equipped with vents to allow gas to escape in the event of a leak As a result...

Страница 3: ...fitting the hob to the worktop position the seal provided along the perimeter of the hob Brackets for fixing hobs to the cabinet have been provided and these should be fitted as shown in detail S fig...

Страница 4: ...ktop it will suffice to leave space for the gas supply tube and electricity supply cable To fit this type of hob follow the instructions below fig 5 Fix the two screws provided A at a distance from th...

Страница 5: ...tance free number 0800 158 55 00 The manufacturer declines any liability should these safety measures not be observed Gas connection This appliance is designated and set to work with the gas indicated...

Страница 6: ...ioned in or next to the tap pin until the flame is small but steady 3 Having adjusted the flame to the required low setting while the burner is alight quickly change the position of the knob from mini...

Страница 7: ...50 0 40 30 60 109 107 88 143 D Double crown wok inner DCDR 30 0 90 0 40 30 44 65 64 70 86 D Double crown wok outer DCDR 2 nozzle 130 4 10 1 30 57 70 298 293 110 390 Supply Pressures Nominal mbar Mini...

Страница 8: ...ose the most appropriate burner to cook with Control knobs allow to adjust the power or the size of the flame The ignition enables a specific burner to be lit automatically when a knob is pushed down...

Страница 9: ...the outside ring to maximum at the same time Pots and pans of all sizes can be used In the case of the smaller pots and pans we recommend the use of only the internal burner There is a separate contr...

Страница 10: ...pan or fish kettle To turn the two burners 90 proceed as follows Make sure that the burners are cool Lift the burner completely out of its housing Replace it in its housing in the position desired Ma...

Страница 11: ...lug from the mains In case of malfunction under no circumstances should you attempt to repair the appliance yourself Repairs carried out by inexperienced persons may cause injury or further malfunctio...

Страница 12: ...burners should be washed frequently with warm water and soap and any burnt on substances removed For hobs which ligth automatically the terminal part of the electronic instant lighting devices should...

Страница 13: ...have pressed the knob all the way in Make sure that you keep the knob pressed in long enough to activate the safety device Make sure that the gas holes are not blocked in the area corresponding to the...

Страница 14: ...egister appliances telephone free on 0800 158 55 00 or visit www scholtes co uk This guarantee is subject to the following conditions The appliance has been installed and operated correctly and in acc...

Страница 15: ...GB 15...

Страница 16: ...GB 16 03 2010 195082269 01 XEROX FABRIANO...

Отзывы: