Burner and nozzle specifications

Table 1

Liquid gas

Natural gas

Burner

Diameter

(mm)

Thermal

power

kW

(p.c.s.*)

Thermal

power

kW

(p.c.s.*)

By-pass

1/100

(mm)

Nozzle

1/100

Flow*

g/h

Thermal

power

kW

(p.c.s.*)

Nozzler

1/100

Flow*

l/h

Nozzler

1/100

Flow*

l/h

Red.

Nom.

(mm)

***

**

Nom.

(mm)

(mm)

Reduced Fast
(RR)

100

0,70

2,60

39

80

189

186

2,60

110

248

135

248

Semi Fast
(Medium) (S)

75

0,40

1,65

28

64

120

118

1,65

96

157

105

157

Auxiliary

(Small) (A)

55

0,40

1,00

28

50

74

71

1,00

79

95

80

95

Mini WOK (MW)

110

1,30

3,50

57

91

254

250

3,50

138

343

155

333

Mini
DUAL

MD
internal

40

0,20

0,60

23

37

44

43

0,70

66

67

76

86

MD
external

108

1,30

4,00

54

93

291

286

4,00

135

381

124

438

Supply
pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

28-30

20
35

37
25
45

20
17
25

13

6,5

18

*

At 15°C and 1013 mbar - dry gas

***

Butane P.C.S. = 49.47 MJ/Kg

**

Propane P.C.S. = 50.37 MJ/Kg

Natural P.C.S. = 37.78 MJ/m

3

A

S

MW

S

SH07GGMAB

A

MD

RR

S

S

SH06GGMAB

 

The hob can only be installed above built-in ovens with a cooling ventilation system.

Main frequency and voltage of the electrical section and characteristics of the gas section

Model

Gas section

Electric section

Class

Rated power

kW (1)

Voltage

SH06GGMAB

II2H3+

7,80 (567 g/h - G30)

(557 g/h - G31)

220-240V~  50/60Hz

SH07GGMAB

10,90 (793 g/h - G30)

(778 g/h - G31)

(1) The values in g/h refer to the capacities with liquid gas (Butane, Propane).

Содержание SH06GGMAB

Страница 1: ...ate Burner and nozzle specifications Electrical Connection 6 Description of the appliance 7 Overall view Start up and use 8 Practical advice on using the burners Precautions and tips 9 General safety...

Страница 2: ...to the floor as it is heavier than air Therefore rooms containing LPG cylinders must also be equipped with vents to allow gas to escape in the event of a leak As a result LPG cylinders whether partial...

Страница 3: ...r to prevent leaks The seal must always be replaced after rotating the pipe fitting seal provided with appliance The gas supply pipe fitting is a threaded 1 2 gas cylindrical male attachment Connectin...

Страница 4: ...ity directives 2006 95 EEC dated 12 12 06 Low Voltage and subsequent amendments 2004 108 EC dated 15 12 04 Electromagnetic Compatibility and subsequent amendments 93 68 EEC dated 22 07 93 and subseque...

Страница 5: ...37 44 43 0 70 66 67 76 86 MD external 108 1 30 4 00 54 93 291 286 4 00 135 381 124 438 Supply pressures Nominal mbar Minimum mbar Maximum mbar 28 30 20 35 37 25 45 20 17 25 13 6 5 18 At 15 C and 1013...

Страница 6: ...wired directly into a 13 amp cable outlet controlled by a switch in compliance with BS 5733 which is accessible without moving the appliance Please note for appliances with a rating greater than 13 am...

Страница 7: ...Knobs for GAS BURNERS adjust the power or the size of the flame SAFETY DEVICES Ignition for GAS BURNERS Control Knobs for GAS BURNERS Control Knobs for GAS BURNERS and ELECTRIC HOTPLATE Support Grid...

Страница 8: ...en cooking with small recipients use only the inner burner The burner is controlled with a single knob To light it press the knob in fully and turn it in an anticlockwise direction until it reaches th...

Страница 9: ...uld you attempt to repair the appliance yourself Repairs carried out by inexperienced persons may cause injury or further malfunctioning of the appliance Contact a Service Centre see Assistance Always...

Страница 10: ...to wash the hob with a damp sponge and dry it with absorbent kitchen roll The removable parts of the burners should be washed frequently with warm water and soap and any burnt on substances removed F...

Страница 11: ...have pressed the knob all the way in Make sure that you keep the knob pressed in long enough to activate the safety device Make sure that the gas holes are not blocked in the area corresponding to the...

Страница 12: ...telephone free on 0800 158 55 00 or visit www scholtes co uk This guarantee is subject to the following conditions The appliance has been installed and operated correctly and in accordance with the o...