GB
5
Burner and nozzle specifications
Table 1
Liquid gas
Natural gas
Burner
Diameter
(mm)
Thermal
power
kW
(p.c.s.*)
Thermal
power
kW
(p.c.s.*)
By-pass
1/100
(mm)
Nozzle
1/100
Flow*
g/h
Thermal
power
kW
(p.c.s.*)
Nozzler
1/100
Flow*
l/h
Nozzler
1/100
Flow*
l/h
Red.
Nom.
(mm)
***
**
Nom.
(mm)
(mm)
Reduced Fast
(RR)
100
0,70
2,60
39
80
189
186
2,60
110
248
135
248
Semi Fast
(Medium) (S)
75
0,40
1,65
28
64
120
118
1,65
96
157
105
157
Auxiliary
(Small) (A)
55
0,40
1,00
28
50
74
71
1,00
79
95
80
95
Mini WOK (MW)
110
1,30
3,50
57
91
254
250
3,50
138
343
155
333
Mini
DUAL
MD
internal
40
0,20
0,60
23
37
44
43
0,70
66
67
76
86
MD
external
108
1,30
4,00
54
93
291
286
4,00
135
381
124
438
Supply
pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
13
6,5
18
*
At 15°C and 1013 mbar - dry gas
***
Butane P.C.S. = 49.47 MJ/Kg
**
Propane P.C.S. = 50.37 MJ/Kg
Natural P.C.S. = 37.78 MJ/m
3
A
S
MW
S
SH07GGMAB
A
MD
RR
S
S
SH06GGMAB
The hob can only be installed above built-in ovens with a cooling ventilation system.
Main frequency and voltage of the electrical section and characteristics of the gas section
Model
Gas section
Electric section
Class
Rated power
kW (1)
Voltage
SH06GGMAB
II2H3+
7,80 (567 g/h - G30)
(557 g/h - G31)
220-240V~ 50/60Hz
SH07GGMAB
10,90 (793 g/h - G30)
(778 g/h - G31)
(1) The values in g/h refer to the capacities with liquid gas (Butane, Propane).