background image

GB

11

Table of contents

Technical characteristics, 12

Electrical connection, 13

Safety measures, 14

Installation, 15

Operation, 16

External exhausting version
Operation with recirculated air

Use of the hood, 18

Lighting, 19

Cleaning, 20

Instructions for 
installation and use

COOKER HOOD

F

GB

D

Français, 1

English, 11

Deutsch, 21

NL

Nederlands, 31

GFE 631
GFI 632
GFI 641

I

Italiano, 41

imp. CAPPA GFE631 GFI -632-641  9-03-2007  18:40  Pagina 11

Содержание GFE 631

Страница 1: ...easures 14 Installation 15 Operation 16 External exhausting version Operation with recirculated air Use of the hood 18 Lighting 19 Cleaning 20 Instructions for installation and use COOKER HOOD F GB D Français 1 English 11 Deutsch 21 NL Nederlands 31 GFE 631 GFI 632 GFI 641 I Italiano 41 ...

Страница 2: ...he cabinet 524 496 depth hole on the bottom side of the cabinet 289 261 height min max 152 Ø of exhausting connection 120 Weight in kg 7 Absorption in watts 220 240 V Rated absorption 280 215 Motor absorption 2 x 100 1 x 175 Lighting absorption Halogen lamp 2 x 40 2 x 20 Metal grease filter Aspiration area cm2 704 ...

Страница 3: ... supply The unit is fitted with an electrical supply chord in compliance with European standards Attention if the appliance is permanently connected to the mains the plug supplied must be removed and safely disposed of The appliance must then be fitted with a bipolar switch in compliance with current regulations and have a minimum contact break of 3 mm The manufacturer will not be held liable for ...

Страница 4: ...ed to If the hood is run at the same time as a burner or fireplace that depend on ambient air for example gas Diesel coal or wood heaters water heaters etc be careful because the hood when it exhausts the air removes the ambient air required by the burner or fireplace for combustion For secure operation and to prevent discharged gas from coming back in the vacuum must not exceed 0 04 mbr This may ...

Страница 5: ...e screws supplied into the F holes and tighten them to fasten the hood to the cabinet Diagram 1 d Remount the frame e Reinstall the filter or grease filters The horizontal sections of the pipe must be slanted slightly upwards about 10 to ensure an easy flow of the air outwards For better efficiency it is advisable to install the hood slightly inwards from the cupboard edge so as to create a recess...

Страница 6: ...nit is obtained in the external exhausting version therefore it is advised where possible to use the external exhausting version External exhausting version In this case the fumes are conveyed outside by means of a special pipe connected with the connection ring located on top of the hood Diagram 2 Diameter of the exhausting pipe must be equal to that of the connection ring 120mm In the horizontal...

Страница 7: ...perated in recirculation mode proceed as follows Mounting and replacing the active charcoal filter Disconnect the hood from the electricity Remove the grease filter s Diagram 1 Release spring C and remove the frame Diagram 1 Insert the charcoal filters turning the knob in the clockwise direction until it stops Diagram 3 Remount the frame as well as the grease filter s following the same steps as b...

Страница 8: ...erates at intensive speed for 5 minutes then returns automatically to the previous state set Fat filters signal this command flashes after 40 hours green Led the fat filters are saturated and should be cleaned Diagram 4 Diagram 5 Carbon filter signal this command flashes after 160 hours red Led Press for 3 seconds to reset both the signals At the end of the operation the signals disappear and a be...

Страница 9: ... grease filter s and the frame Replace the faulty lamp with a new one of the same kind and technical characteristics Refit the frame and the grease filter s Before calling for technical assistance because the hood fails to light up make sure the lamps are well mounted ...

Страница 10: ...ging it before putting it back into place Replacing the carbon filter These filters normally last about six months However they cannot be cleaned or recycled Therefore they must be replaced when no longer useable To fit or replace see page 16 Important The manufacturers do not accept responsibility for any damage to the motor or for fires because of failure to perform maintenance operations as pre...

Отзывы: