WHAT IS WRONG?
The appliance may not function at all or does not functioning
properly. Before calling the after-sales service, let’s see what
we can to do.
Check that there is no cutting of the gas or electricity
supply, and if the gas valves on the appliance are opened
properly.
The burner is not igniting or the flame is not uniform.
Have you checked if:
• the gas outlets are not hazardously blocked.
• the detachable pieces forming the burner have been
mounted correctly.
• there are air currents in the proximity of the hob.
The flame does not remain ignited.
Have you checked if:
• you have pressed the knob well.
• you have pressed and held the knob for a period of time,
enough to allow the safety device to connect.
• the gas outlets situated on the safety device are not
hazardously blocked.
The burner goes out when it is adjusted to the
minimum flame position.
Have you checked if:
• the gas outlets are not hazardously blocked
• there are air currents in the proximity of the hob
• the minimum flame has been adjusted correctly (See
paragraph ‘’Minimum adjustment ").
The saucepans are unstable.
Have you checked if:
• the base of the saucepan is perfectly flat
• the saucepan is placed well on the centre of the burner
If, despite all these steps, your appliance still does not
function and the problem persists, call the nearest After-
Sales Service of Merloni Elettrodomestici and be specific
with:
- the type of fault.
- the logo of the model (Mod. ...) indicated in the warranty
certificate.
Never contact unauthorised technicians and always refuse
the installation of spare parts which are not original.
CHARACTERISTICS OF BURNERS AND INJECTORS
Table 1
Liquid gases
Natural gases
Burner
diameter
(mm)
Thermal power
kW (H.s.*)
By-pass
1/100
(mm)
Injector
1/100
(mm)
Output*
g/h
Injector
1/100
(mm)
Output*
l/h
BURNER
Nom.
Red.
G30 G31
G20 G25
C.
Rapid 100
3.00
0.7
40
86
218
214
116
286
332
B.
Semi-rapid 75
1.90
0.4
30
70
138
118
106
181
210
A.
Auxiliary 55
1.00
0.4
30
50
73
71
79
95
111
D.
Triple Crown (Liquid gases) 130 3.25 1.5 63
91 236
232
D.
Triple Crown (Natural gases) 130 3.40 1.5
133 324
376
Pressure of supply
Nom.(mbar)
Min.(mbar)
Max.(mbar)
28-30
20
35
37
25
45
20
17
25
25
20
30
* At 15°C and 1013 mbar-gas dry
Gas Propane G31 H.s. = 50,37 MJ/kg
Gas Butane G30
H.s. = 49,47 MJ/kg
Gas Methane G20
H.s. = 37,78 MJ/m3
Gas G25
H.s. = 32,49 MJ/m3
This appliance conforms to the following
Community Directives:
-
73/23/
EEC
of 19/02/73 (Low Voltage) and
successive amendments;
-
89/336/
EEC
of 03/05/89 (Electromagnetic
compatibility) and successive amendments;
-
90/336/
EEC
of 29/06/90 (Gas) and successive
amendments;
-
93/68/
EEC
of 22/07/93 and successive amendments.
OVEN TECHNICAL CHARACTERISTICS
ENERGY LABEL
Directive 2002/40/EC on the labelling of electric ovens
Norm EN 50304
Energy consumption natural convection:
oven function :
Static
Energy consumption declared for forced convection
Class:
oven function :
Convection
11