background image

GBA B 0705 0 E 

 

BA 

Page 1 of 24 

November 17, 2015 

Last revised 11-2015 

 

Rev. 0 

Scho

ll Ap

parat

eb

au

 G

mb

H & 

C

o

KG

 

 

 

Instructions for Use 

Coated quartz built-in module 

Heat and light 

Model-No. 

Art. No. 

Power 

29000/S 

B 0705 

400W 

 

 

 

 

 

 

 

 

 

Scholl Apparatebau GmbH & Co. KG 

Zinhainer Weg 4 
D–56470 Bad Marienberg/Germany 
 
Phone   

+0049 (0) 2661 – 9868-10 

Fax 

 

+0049 (0) 2661 – 9868-38 (Service) 

Internet  

www.scholl-gastro.de 

E-mail   

[email protected] 

 

Содержание 29000/S

Страница 1: ...G Instructions for Use Coated quartz built in module Heat and light Model No Art No Power 29000 S B 0705 400W Scholl Apparatebau GmbH Co KG Zinhainer Weg 4 D 56470 Bad Marienberg Germany Phone 0049 0...

Страница 2: ...ion regarding compliance with standards laws and directives 8 2 3 Safety 8 3 Packing transport intermediate storage scope of delivery 9 3 1 Packing 9 3 2 Transport 9 3 3 Intermediate storage 9 3 4 Sco...

Страница 3: ...data 17 8 1 Dimensioned drawing 18 8 2 Circuit diagram 19 8 3 Spare parts list 20 8 4 Exchange of the IRK halogen infrared quartz radiator 21 9 Disposal and Environmental Notes 22 9 1 Disposal of pac...

Страница 4: ...fully before starting up this appliance On the following pages you will find important notes regarding its operation care and maintenance so that you will be able to enjoy its use for a long time If a...

Страница 5: ...ttempt to carry out repairs on this appliance yourself Connect this appliance to suitably earthed mains outlets only Ensure that your mains power supply conforms to the data stated on the nameplate of...

Страница 6: ...tive oxygen chlorine or caustic corrosive constituents abrasive cleaning products such as scouring creams pastes steel wool sa ponified steel wool metal or plastic sponges or sponges with a scratchy s...

Страница 7: ...GER electrical voltage indicates an immediately threatening hazard Failure to observe this warning notice will result in severe physical injury or death CAUTION IMPORTANT Improper use may result in mi...

Страница 8: ...This appliance conforms to the following Standards laws directives 2006 95 EG Low Voltage Directive DIN EN 60335 1 Household and similar electrical appliances Safety Part 1 General requirements DIN EN...

Страница 9: ...ular care must be exercised during shipping and handling of this appliance to prevent damage result ing from exposure to excessive force or careless loading unloading Shocks during shipping and handli...

Страница 10: ...air circulation above the coated quartz built in module The complete device must be protected against heat congestion and waste heat if necessary through suita ble cooling or ventilation Install the c...

Страница 11: ...e appliance into service observe the following Faulty equipment must not be taken into operation Legal requirements and the connection conditions of your local power supply company must be fully obser...

Страница 12: ...f the coated quartz built in module Do not touch the IRK halogen infrared quartz radiator and the device surfaces The IRK halogen infrared quartz radiator and the surfaces of the device will become ho...

Страница 13: ...itch to OFF Instead the mains plug must be pulled or the electrical circuit must be de energized respectively Check that no voltage is present before opening the appliance and lock out the circuit to...

Страница 14: ...t may be used Never use any of the following for cleaning aggressive or bleaching products i e containing active oxygen chlorine or caustic corrosive constituents abrasive cleaning products such as sc...

Страница 15: ...ror Repairs are not free of charge even within the warranty period if the problem is caused by an operating error or if you have failed to observe any of the following instructions Before any cleaning...

Страница 16: ...does not heat IRK halogen infrared quartz radiator faulty Exchange IRK halogen infrared quartz radiator To be remedied by an electrical specialist Appliance does not heat No voltage supply Check volta...

Страница 17: ...TECHNICAL DATA Voltage 230V Power 400W Model No 29000 S Art No B 0705 Design Casing made of chrome nickel steel 18 10 With IRK halogen infrared quartz radiator coated with safety glass hub With 2 thre...

Страница 18: ...GBA B 0705 0 E BA Page 18 of 24 November 17 2015 Last revised 11 2015 Rev 0 Scholl Apparatebau GmbH Co KG 8 1 DIMENSIONED DRAWING Model No Art No Power 29000 S B 0705 400W...

Страница 19: ...0705 0 E BA Page 19 of 24 November 17 2015 Last revised 11 2015 Rev 0 Scholl Apparatebau GmbH Co KG 8 2 CIRCUIT DIAGRAM Model No Art No Power 29000 S B 0705 400W Key E1 IRK halogen infrared quartz rad...

Страница 20: ...by an author ized professional observing applicable safety regulations Improperly executed work will put your safety at risk Spare parts list Art No B 0705 component label TB 026731 socket protection...

Страница 21: ...be pulled or the electrical circuit must be de energized respectively Check that no voltage is present before opening the appliance and lock out the circuit to make it safe against re energizing Alway...

Страница 22: ...your area please contact your local government or community admin istration 9 2 DISPOSAL OF THE APPLIANCE Render the appliance inoperable before disposal Pull the plug out of the socket outlet or arr...

Страница 23: ...damage involving factors unrelated to the appliance will be accepted Further warranty information is contained in our Gen eral Terms and Conditions of Sale or can be made available upon request Applia...

Страница 24: ...times Monday Thursday from 7 00 a m till 4 00 p m Fridays from 7 00 a m till 12 15 p m Outside these office hours please communicate your requests per e mail or telefax Scholl Apparatebau GmbH Co KG...