Страница 1: ...with folding doors 20060 SO FU 20100 SO FU State September 2006 Operating Manual Rev 0 2006...
Страница 2: ...Contents IV 1 Environmental information UW 2 General information AL 3 Safety SI 4 7 Technical details TE 8 9 Transport TR 10 Commissioning IN 11 Operation BE 12 Cleaning RE 13 Stock keeping of replac...
Страница 3: ...rly disposed according to environmental requirements Warning Manufacturer can not be made liable if damages are caused upon non observance of the following instructions 1 The handling of this device a...
Страница 4: ...lectrical installations 5 In case of care and maintaining works disconnect device from the electric circuit by switching off the main switch or quitting the voltage of the power supply 6 Don t leave t...
Страница 5: ...ying of the device has to be prevented 2 Operational safety recommendations 2 1 Appropriate use Device has been manufactured according to the current state of the art technology and to the acknowledge...
Страница 6: ...es has to be carried out immediately after finishing the maintenance and repair works Before putting into operation after maintenance works make sure that all protection advices have been mounted Prov...
Страница 7: ...r kinds of danger 3 2 Electrical energy Use only genuine fuses with prescribed strength of current In case of disturbances in power supply switch off device immediately Works at electrical installatio...
Страница 8: ...g the switching on of the device before use high temperatures can be reached around the heating Please check the surface before you start working there Don t put paper cardboard cloth etc between devi...
Страница 9: ...800 700 850 1000 230 20090 SO FU 900 700 850 2 x 630 W 230 20100 SO FU 1000 700 850 2 x 630 W 230 Design Chrome nickel steel 18 10 With feet 150mm Adjustable intermediate shelf Thermostatically adjust...
Страница 10: ...ransport the device with particular care in order to avoid damage by violent impacts or careless loading and unloading Shocks during transport have to be avoided Device has to be treated with care 3 I...
Страница 11: ...t 2 At commissioning During the putting into operation has to be checked Defect devices are not allowed to put into operation Protect the cable from oil and grease Handling Connect device by means of...
Страница 12: ...ed for the operation of the device All electrical repairs have to be done by authorized specialists 1 1 Repair of disturbances Symptoms Reasons Measures device does not heat up thermostat or heating d...
Страница 13: ...y wipe device with a wet tissue using a mild cleaner if necessary Don t use cleaning powder SECURITY ADVISES Don t use high pressure cleaner Don t treat device with acids or expose it to acid vapour O...
Страница 14: ...0 05 heating for 20060 20070 750 W order no 71 20 05 heating for 20080 1000 W order no 71 20 06 heating for 20090 20100 2 x 630 W order no 71 10 03 socket for signallamp round untill July 2008 order n...
Страница 15: ...Hot cupboard w folding doors 20060 20100 SO FU STATE SEPTEMBER 2006 14 Wiring Diagram SB H1 Contoll lamp R1 Heating S1 Thermostat...
Страница 16: ...OLL Apparatebau GmbH Co KG Zinhainer Weg 4 56470 Bad Marienberg Ww Replacement parts sales Telephone 2661 9868 34 35 Telefax 2661 9868 38 E mail service scholl gastro de Technical services Telephone 2...