Mounting instructions 

During operation, the environment temperature at the connection head must not fall 

below 

-20°C

 and the environment temperature of 

+40°C

 must not be exceeded. 

Should the environment temperature deviate from these values, the device must be 

switched off. (An appropriate room-temperature control must e.g. be provided). 

 

The connection head must not be provided with thermal insulation, otherwise the 

connection area is overheated. 

Max. permissible temperature at the connection area: 80°C. 

 

 

 

Mounting 

Mounting position: 

horizontal 

 

Installation note: 

• 

When installing the device, make sure that it 

is not damaged. (Heating elements, …) 

• 

Choose a seal witch is suitable for the medium. 

• 

Choose suitable screws. 

• 

Bolt the device flange with the installation flange. 

• 

Check tightness. 

• 

Re-tighten after the first heating (if necessary). 

 

The device must be fixed tightly. 

 

During operation the heating element must be covered by the medium to be heated, 

otherwise overheating may occur. 

Therefore, the customer must provide 

level monitoring

 ensuring that the device can only 

be operated with sufficient covering (50 mm approx.) of the heating elements. 

 

The electrical connection head and the cooling lenght (the range between flange and 

connection head) may not be isolated. 

 

The temperature regulation and / or temperature limitation is to be planned / connected by the 

builder/operator 

 

Содержание 20153106330140

Страница 1: ...ber 20153106330140 Cartridge type heater Type 93 F53 63 Output W 1 000 Output tolerant 5 10 Voltage 400V 2 Schniewindt GmbH Co KG Sch ntaler Weg 46 58809 Neuenrade Germany Phone 49 2392 692 0 Fax 49 2...

Страница 2: ...on the product 3 2 Intended use 3 3 Safety 4 4 Connection and performance data 5 5 Mounting instructions 6 6 Mounting 6 7 Installation 7 8 Initial start up 8 9 Repair of failures 8 10 Repair 9 11 Mai...

Страница 3: ...its correctly fitted cable The screw insertion the cable gland and the inserted cable must be in a resting position A fixed cable gland is observed The cable gland must not be considered only as a sin...

Страница 4: ...ifications lead to invalidation of conformity Note the mounting position of the device or direction of flow of the medium to be heated when they are given Carry out periodic inspections in accordance...

Страница 5: ...ube mm 52 Operating data Medium oil Operating temperature C 40 Max allowed temperature TS C 80 Max allowed pressure PS bar g 0 5 Connection head Dimensions connection head mm 108 x 108 x 90 red RAL 30...

Страница 6: ...ation note When installing the device make sure that it is not damaged Heating elements Choose a seal witch is suitable for the medium Choose suitable screws Bolt the device flange with the installati...

Страница 7: ...lation resistance amounts to no more than 50 Ohm V related to the calculation tension The supply voltage must correspond to the voltage indicated on the type plate For the selection of the cross secti...

Страница 8: ...ements Set a temperature controller to the target temperature Guarantee that the temperature controller is duly attached Guarantee that the on site temperature limitation is duly attached By a tempera...

Страница 9: ...k the thermostat and or limiter function Visual inspection for damage Visual inspection for deposits or incrustations on the heating elements Visual inspection for leaks Visual inspection of the elect...

Страница 10: ...if necessary the cable entries must be equipped with blinds Place a drying agent in the connection area to absorb existing humidity Use only chemically indifferent drying agents e g silica gel Change...

Отзывы: