en
5
Mounting instructions
During operation, the environment temperature at the connection head must not fall
below
-20°C
and the environment temperature of
+40°C
must not be exceeded.
Should the environment temperature deviate from these values, the device must be
switched off. (An appropriate room-temperature control must e.g. be provided).
The connection head must not be provided with thermal insulation, otherwise the
connection area is overheated.
Max. permissible temperature at the connection area: 80°C.
6
Mounting
Mounting position:
horizontal
Installation note:
•
When installing the device, make sure that it
is not damaged. (Heating elements, …)
•
Choose a seal witch is suitable for the medium.
•
Choose suitable screws.
•
Bolt the device flange with the installation flange.
•
Check tightness.
•
Re-tighten after the first heating (if necessary).
The device must be fixed tightly.
During operation the heating element must be covered by the medium to be heated,
otherwise overheating may occur.
Therefore, the customer must provide
level monitoring
ensuring that the device can only
be operated with sufficient covering (50 mm approx.) of the heating elements.
The electrical connection head and the cooling lenght (the range between flange and
connection head) may not be isolated.
The temperature regulation and / or temperature limitation is to be planned / connected by the
builder/operator