background image

 
 
 

 

Page 1 of 10 

Create date 22.02.2019 

en

 

Only for use in a commercial environment! 

Instruction manual 

Article-number: 20153106330140 

Cartridge type heater 

Type  

 

: 93/F53-63 

Output  

(W) 

: 1,000 

Output tolerant 

(%) 

: +5/-10 

Voltage  

 

: 400V 2~ 

Schniewindt GmbH & Co. KG 

Schöntaler Weg 46 

58809 Neuenrade, Germany 

Phone:  

+49 2392 692-0 

Fax:  

+49 2392 692-11 

[email protected]

 

www.schniewindt.de

 

Translation 

Created for the applicable standards in Germany 

Содержание 20153106330140

Страница 1: ...ber 20153106330140 Cartridge type heater Type 93 F53 63 Output W 1 000 Output tolerant 5 10 Voltage 400V 2 Schniewindt GmbH Co KG Sch ntaler Weg 46 58809 Neuenrade Germany Phone 49 2392 692 0 Fax 49 2...

Страница 2: ...on the product 3 2 Intended use 3 3 Safety 4 4 Connection and performance data 5 5 Mounting instructions 6 6 Mounting 6 7 Installation 7 8 Initial start up 8 9 Repair of failures 8 10 Repair 9 11 Mai...

Страница 3: ...its correctly fitted cable The screw insertion the cable gland and the inserted cable must be in a resting position A fixed cable gland is observed The cable gland must not be considered only as a sin...

Страница 4: ...ifications lead to invalidation of conformity Note the mounting position of the device or direction of flow of the medium to be heated when they are given Carry out periodic inspections in accordance...

Страница 5: ...ube mm 52 Operating data Medium oil Operating temperature C 40 Max allowed temperature TS C 80 Max allowed pressure PS bar g 0 5 Connection head Dimensions connection head mm 108 x 108 x 90 red RAL 30...

Страница 6: ...ation note When installing the device make sure that it is not damaged Heating elements Choose a seal witch is suitable for the medium Choose suitable screws Bolt the device flange with the installati...

Страница 7: ...lation resistance amounts to no more than 50 Ohm V related to the calculation tension The supply voltage must correspond to the voltage indicated on the type plate For the selection of the cross secti...

Страница 8: ...ements Set a temperature controller to the target temperature Guarantee that the temperature controller is duly attached Guarantee that the on site temperature limitation is duly attached By a tempera...

Страница 9: ...k the thermostat and or limiter function Visual inspection for damage Visual inspection for deposits or incrustations on the heating elements Visual inspection for leaks Visual inspection of the elect...

Страница 10: ...if necessary the cable entries must be equipped with blinds Place a drying agent in the connection area to absorb existing humidity Use only chemically indifferent drying agents e g silica gel Change...

Отзывы: