background image

11

Should you have any questions regarding the instrument or Operating Instructions, or their 
use, please indicate above all the following details which are given on the ID plate: 
  1) Model 
  2) Serial number

Notes:

8  Correspondence

To avoid unnecessary follow-up questions, and the resulting loss of time or 

possible misunderstandings, please return the instrument with a detailed fault 

description to our service department. Please indicate in your order whether you 

require an Inspection Certificate 3.1 according to DIN EN 10204.

9  Repairs

HANS SCHMIDT & Co GmbH 

Schichtstr. 16 

D-84478 Waldkraiburg 

Germany

Service address:

Shipping instructions:

We kindly ask for return free of charge for us, if possible by airmail parcel. All occurring 
charges, if any (such as freight, customs clearance, duty etc.), will be billed to customer. 
For return from foreign countries, we ask you to include a proforma invoice with a low value 
for customs clearance only, e.g. 50 Euro, each and to advise the shipment in advance by 
fax or eMail.

Содержание ZD2

Страница 1: ...Tension Meter Z Series Model ZF2 Edition ZF 03 2 E Instruction Manual Valid as of 01 02 2007 Please keep the manual for future reference S C H M I D T c o n t r o l i n s t r u m e n t s ...

Страница 2: ...ht 4 1 9 Declaration of Conformity 4 2 Available Models 5 2 1 Specifications 5 2 2 Delivery Includes 6 2 3 Unpacking 6 3 Initial Setup and Operating Procedure 6 3 1 Notes Before Starting Measurement 6 3 2 Operating Elements of the Tension Meter 7 3 3 Measuring with the Tension Meter 7 3 4 Checking the Measuring Accuracy 8 4 Service and Maintenance 9 4 1 Rollers 9 5 Cleaning 9 6 Verification Interv...

Страница 3: ...the device Insufficient inspection of device components that are subject to wear Opening the device or improper repair work Disasters caused by the effects of foreign objects or by force majeure 1 1 Notices within the Operating Instructions The fundamental prerequisite for the safe handling of this device and its troublefree opera tion is the knowledge of the basic safety notices and safety instru...

Страница 4: ...hall HANS SCHMIDT Co GmbH be held liable for damage resulting from misuse The intended use also includes Complying with all notices included in the Operating Instructions and observing all inspection and maintenance works 1 8 Copyright 1 9 Declaration of Conformity The copyright on these Operating Instructions remains with the company HANS SCHMIDT Co GmbH These Operating Instructions are intended ...

Страница 5: ...2 100 10 100 43 PA 0 12 mm Ø 2 Available Models These Operating Instructions refer to Model ZD2 of the Z Series The individual models of the Z Series are also available with the following modifications customized versions Special tension ranges Calibration for material path other than standard vertical Calibration to different units of measure such as g 2 1 Specifications Calibration According to ...

Страница 6: ...nt you must put on your personal protective clothing if necessary For example eye protectors gloves etc To avoid damage do not move the center roller by hand Tensions that exceed the tension range of the instrument by more than 100 may cause permanent damage to the measuring spring and must be avoided under any circumstances Do not turn the outer ring of the movement the measured values will oth e...

Страница 7: ... the measured material runs smoothly between the GUIDE ROLLERS and the MEASURING ROLLER It is essential that the THUMBPIECE return slowly to its initial position Any uncontrolled snap back may affect calibration and may also damage the instrument The SCALE pointer will now show the line tension directly Removing Push the THUMBPIECE as far as it will go in the direction of the arrow With the GUIDE ...

Страница 8: ...h portion of the material to be measured Push the THUMBPIECE as far as it will go in the direction indicated by the arrow and thread the material to be measured between the GUIDE ROLLERS and the MEASURING ROLLER Refer to Chapter 3 2 Slowly release pressure on the THUMBPIECE until the GUIDE ROLLERS return to their original position It is essential that the THUMBPIECE return slowly to its initial po...

Страница 9: ... rollers 900 m min with mounting wrench or Model ZF2 12 K on the rear of the tension meter Serial number Z 211 888888 on the rear of the tension meter Roller Code K Order number R521106 Supply 1 set 3 pieces spare rollers 2000 m min with mounting wrench 5 Cleaning For cleaning the unit do not use any AGGRESSIVE SOLVENTS such as trichloroethylene or similar chemicals NO WARRANTY OR LIABILITY shall ...

Страница 10: ... customer No Yes No Yes No Yes Vertification of the calibration Visual inspection and functional test Values within specification Prepare certification for incoming calibration Determination of costs Make of cost estimate Repair and adjustment Verification of the calibration Calibration label on the instrument No Invoice scrapping and disposal Invoice repair and calibration services and dispatch I...

Страница 11: ...rvice department Please indicate in your order whether you require an Inspection Certificate 3 1 according to DIN EN 10204 9 Repairs HANS SCHMIDT Co GmbH Schichtstr 16 D 84478 Waldkraiburg Germany Service address Shipping instructions We kindly ask for return free of charge for us if possible by airmail parcel All occurring charges if any such as freight customs clearance duty etc will be billed t...

Страница 12: ...Thickness Gauge Yarn Package Durometer and Shore A Durometer Sample Cutter Balance Moisture Meter Leak Tester Softometer Mailing address P O B 1154 84464 Waldkraiburg Germany Shipping address Schichtstr 16 84478 Waldkraiburg Germany Hans Schmidt Co GmbH Phone int 49 0 8638 9410 0 Fax int 49 0 8638 4825 int 49 0 8638 67898 More than 70 years Worldwide e mail info hans schmidt com Internet http www ...