The device was designed according to the state of the art and the approved safety stan-
dards. Nevertheless, its use may cause serious or fatal injury to the user or third persons, 
and/or an impairment of the device or of other material assets.

The device must not be operated in potential explosive areas 

and must not come into contact with aggressive substances.

The device may only be applied: 
- For its intended use in a faultless condition with regard to the safety requirements. 
- Malfunctions that could impair safety must be remedied immediately. 
- Personal protective equipment must be used according to the EC Directive 89/686/EEC.

The Operating Instructions must always be kept on hand where the device is operated. 
Apart from the Operating Instructions, the generally and locally valid regulations on acci-
dent prevention and environmental protection must be provided and complied with.

1.4  Informal Safety Measures

1.6  Intended Use

1.7  Dangers in Handling the Device

The device is intended exclusively to be used as a tension meter for non-moving, preten-
sioned ropes. 
Any other use or any use exceeding this intention will be regarded as misuse. 
Under no circumstances shall HANS SCHMIDT & Co GmbH be held liable for damage 
resulting from misuse. 
The intended use also includes: 
- Complying with all notices included in the Operating Instructions and observing all  
  inspection and maintenance works.

1.8  Copyright

The copyright on these Operating Instructions remains with the company 
HANS SCHMIDT & Co GmbH. 
These Operating Instructions are intended for the operating company and its personnel 
only. They contain instructions and notices that may only be reproduced on the prior writ-
ten permission of 
HANS SCHMIDT & Co GmbH 
and under indication of the complete reference data. 
Violations will be prosecuted.

1.5  Training of the Personnel

Only trained and instructed personnel is permitted to work with the device. The responsi-
bilities of the personnel must be clearly defined for mounting, commissioning, operation, 
setup, maintenance and repair. Trainees may only work with the device under the supervi-
sion of an experienced personnel

1.9  Declaration of Conformity

Our mechanical tension meters do not belong to the EU machinery directive 2006/42/EC 
and do not have a CE mark.

Содержание DNW-100K

Страница 1: ...Tension Meter DN Series Model DNW Edition DNW 01 E Operating Instructions Valid as of 01 12 2015 Please keep the manual for future reference S C H M I D T c o n t r o l i n s t r u m e n t s ...

Страница 2: ...ce 4 1 8 Copyright 4 1 9 Declaration of Conformity 4 2 Available Models 5 2 1 Specifications 5 2 2 Delivery Includes 5 2 3 Unpacking 5 3 Measuring 6 3 1 Notices Before Starting Measurement 6 3 2 Operating Elements of the Tension Meter 7 3 3 Measuring with the Tension Meter 8 3 4 Verification of the DXH calibration 9 4 Service and Maintenance 10 5 Cleaning 10 6 Verification Intervals 10 6 1 Verific...

Страница 3: ...the device Insufficient inspection of device components that are subject to wear Opening the device or improper repair work Disasters caused by the effects of foreign objects or by force majeure 1 1 Notices within the Operating Instructions The fundamental prerequisite for the safe handling of this device and its troublefree opera tion is the knowledge of the basic safety notices and safety instru...

Страница 4: ...er for non moving preten sioned ropes Any other use or any use exceeding this intention will be regarded as misuse Under no circumstances shall HANS SCHMIDT Co GmbH be held liable for damage resulting from misuse The intended use also includes Complying with all notices included in the Operating Instructions and observing all inspection and maintenance works 1 8 Copyright The copyright on these Op...

Страница 5: ...lable Models 2 1 Specifications Calibration According to SCHMIDT factory procedure Accuracy 3 full scale FS or 1 graduation on scale Scale diameter 54 mm Temperature range 10 45 C Air humidity 85 RH max Housing material Die cast aluminium Housing dimensions 260 mm x 268 mm x 120 mm L x W x H Weight net gross Approx 1100 g approx 2400 g 1Tension meter 1Certificate of Compliance with the order 2 1 u...

Страница 6: ...eye protectors gloves etc To avoid damage do not move the measuring pin by hand Tensions that exceed the tension range of the instrument by more than 100 may cause permanent damage to the movement and must be avoided under any circumstances The ID plate with the serial number as well as the calibration label optional are provided on the bottom of the instrument the SCHMIDT Quality Seal are pro vid...

Страница 7: ...7 3 2 Operating Elements of the Tension Meter fig 3 2b fig 3 2a PROCESS MATERIAL MEASURING ROLLER SCALE SPECIAL LEVER GUIDE ROLLERS ...

Страница 8: ...ATERIAL lies smoothly between the GUIDE ROLLERS and the MEASURING ROLLER The scale pointer will now show the line tension directly Inserting Removing Push the SPECIAL LEVER as far as it will go in the direction of the arrow see fig 3 2b With the GUIDE ROLLERS extended move the instrument away from the PROCESS MATERIAL Slowly release pressure on the Thumb piece until the GUIDE ROLLERS return to the...

Страница 9: ... longer allowed the instrument has to be recalibrated or repaired For recalibration return the tension meter to the factory All tension meters of type DNW are calibrated with steel ropes according the SCHMIDT factory procedure The filament sizes are noted in Chapter 2 Any difference in process material size and rigidity from the standard material may cause a deviation of the accuracy In 95 of all ...

Страница 10: ...load of the SCHMIDT tension meter Tolerance band defined by the customer Changes of the tolerance band compared to previous verifications of calibration Therefore the interval between verifications must be determined by the user s Quality Assurance Department based on the user s experience Assuming normal operating time and load as well as careful handling of the tension meter we recommend a verif...

Страница 11: ...y customer No Yes No Yes No Yes Vertification of the calibration Visual inspection and functional test Values within specification Prepare certification for incoming calibration Determination of costs Make of cost estimate Repair and adjustment Verification of the calibration Calibration label on the instrument No Invoice scrapping and disposal Invoice repair and calibration services and dispatch ...

Страница 12: ...ldkraiburg Germany Service address Shipping instructions We kindly ask for return free of charge for us if possible by airmail parcel All occurring charges if any such as freight customs clearance duty etc will be billed to customer For return from foreign countries we ask you to include a proforma invoice with a low value for customs clearance only e g 50 Euro each and to advise the shipment in a...

Отзывы: