04 English
42
Cleaning the outlet
The outlet cover is provided with a plug-in closure. To remove the outlet cover
carefully pull on the cover and lift it out.
Loosen the screws with a no. 3 Allan key and remove the grey plastic sieve. The
valve disc is now visible.
To dismantle the valve disc, open the outlet (turn the revolving rose anti-clock-
wise up to the stop) and pull the valve disc out with slight force beyond the
click point. Any hair and other dirt can now be removed.
After cleaning, press the valve disc in beyond the click point with a slight pres-
sure and check that the outlet can be opened and closed. Replace the grey
plastic sieve and tighten the screws with the Allan key. Insert the outlet cover
and turn slightly clockwise up to the stop.