schmersal TESK Series Скачать руководство пользователя страница 1

TESK

Operating instructions

Hinge safety switch

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear. The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

 selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

 manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

 instructions manual, the country-specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

 provided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

Content

1  About this document 

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2  Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5  Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Adjustment and inspection of the switching angle . . . . . . . . . . . . . .4

3.3  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .6

4.2  Contact variants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

4.3  Switch travel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

5  Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

6  Disassembly and disposal

6.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

6.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

7  Appendix

7.1  Wiring configuration and connector accessories . . . . . . . . . . . . . . .7

7.2  Door gap calculation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

7.3  Load specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

8  EU Declaration of conformity

x.000 / 06.2016 / v

.A.   -   103005958-EN / B / 2016-03-16 / 

AE-Nr

. 5816

EN

Operating instructions. . . . . . . . . . . .pages 1 to 10

Original

Содержание TESK Series

Страница 1: ...ively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as well as all prevailin...

Страница 2: ...ne movable safety guards from being opened before hazardous conditions have been eliminated They are also suitable for fitting on profile sections and existing equipment Hinge safety switches can only be used for applications in which the hazardous condition is terminated without delay e g run on movements when the safety guard is opened The user must evaluate and design the safety chain in accord...

Страница 3: ...specific parameters hop dop and tcycle as well as the load If multiple safety components are wired in series the Performance Level to ISO 13849 1 will be reduced due to the restricted error detection under certain circumstances 3 Mounting 3 1 General mounting instructions During fitting of the actuator and the sensor the requirements of ISO 14119 especially paragraph 7 must be observed Four elonga...

Страница 4: ...see table chapter 7 2 Determining door gap 2 Use the adjustment tool to set the normally closed contacts in such a way that they are securely opened with the maximum permissible door gap Turning clockwise results in a smaller switch angle while turning anticlockwise results in a larger switch angle fig 6 this is the opposite when mounted inside To decrease the switching angle turn counterclockwise...

Страница 5: ...urements in mm TESK S TESK ZS 116 101 6 1 66 8 82 20 78 15 15 5 15 40 17 5 TESK L TESK ZL 60 15 15 5 37 5 15 20 6 1 116 66 8 82 20 98 101 TESK ST 11 TESK L Ø 6 6 70 70 B Ø 5 8 C D Key B Minimum bending radius of the connection cable C Cable 5 core B 29 mm D Cable 9 core B 33 mm ...

Страница 6: ...1 4 TESK 11ST 11 23 12 24 PE 1 2 3 4 5 3 2 5 1 4 4 3 Switch travel TESK 22 TESK 13 10 180 3 11 12 31 32 43 44 23 24 A A 10 180 3 11 12 31 32 41 42 23 24 A A A TESK 12 TESK 02 10 180 3 11 12 31 32 23 24 A A 10 180 3 11 12 21 22 A A TESK 11 10 180 3 11 12 23 24 A Key A Positive break NC contact T Positive break travel angle Switching angle tolerance 1 3 5 Set up and maintenance 5 1 Functional testin...

Страница 7: ...M12 8 pole 5 8 4 3 2 1 7 6 Pin configuration of the connector Colour code or conductor numbering of the below mentioned Schmersal connectors Possible colour code of other commercially available connectors to EN 60947 5 2 2007 DIN 47100 Connecting cables with female connector IP67 M12 8 pole 8 x 0 23 mm 1 BN 1 BN WH 2 WH 2 WH BN Cable length Part number 3 BU 3 BU GN 2 5 m 5 0 m 10 0 m 103011411 103...

Страница 8: ... 109 7 127 9 146 1 164 2 182 2 1 100 57 5 76 7 95 8 114 9 134 0 153 0 172 0 190 9 1 150 60 2 80 2 100 2 120 1 140 1 160 0 179 8 199 6 1 200 62 8 83 7 104 5 125 4 146 2 166 9 187 6 208 3 1 250 65 4 87 2 108 9 130 6 152 3 173 9 195 4 217 0 1 300 68 0 90 6 113 2 135 8 158 4 180 8 203 3 225 6 1 350 70 6 94 1 117 6 141 0 164 4 187 8 211 1 234 3 1 400 73 2 97 6 122 0 146 3 170 5 194 7 218 9 243 0 1 450 ...

Страница 9: ...r doors the have three hinges make sure the two of the hinges are located in the upper third We recommend that the safety hinge switch is placed in the middle when three hinges are used The hinge safety switch must not be used as an end stop For applications in which heavy doors are used especially if these can close with little or no braking effect further measures are to be implemented to preven...

Страница 10: ...lation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal April 20 2016 Authorised signature Philip Schmersal Managing Director EU Declaration of conformity Original K A Schmersal GmbH Co KG Möddinghofe 30 42279 Wuppertal Germany Internet www schmersal com We hereby certify that the hereafter described components both in their basic design...