schmersal SRB301HC/T-24V Скачать руководство пользователя страница 2

2

Operating instructions
Safety-monitoring module

SRB301HC/T-24V

SRB301HC/T-230V

EN

There are no residual risks, provided that the safety instructions as well 
as the instructions regarding mounting, commissioning, operation and 
maintenance are observed.

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of  
the safety-monitoring module, personal hazards or damage  
to machinery or plant components cannot be excluded.  
The relevant requirements of the standards EN 1088 and  
EN ISO 13850 must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 
defective mounting or failure to comply with this operating instructions 
manual. The manufacturer shall accept no liability for damages result-
ing from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary re-
pairs, conversions and modifications to the device are strictly forbidden; 
the manufacturer shall accept no liability for damages resulting from 
such invasive work, arbitrary repairs, conversions and/or modifications 
to the device.

The safety-monitoring module must only be used when the enclosure is 
closed, i.e. with the front cover fitted.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

SRB301HC/T-

No.

Option

Description

24V

24 VAC/DC

230V

48 … 240 VAC

Only if the information described in this operating instructions 
manual are realised correctly, the safety function and therefore 
the compliance with the Machinery Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 
these specifications apply accordingly, provided that they correspond to 
the standard version.

2.3  Destination and use

The safety-monitoring modules for integration in safety circuits are de-
signed for fitting in control cabinets. They are used for the safe evalua-
tion of the signals of positive break position switches for safety functions 
on sliding, hinged and removable safety guards as well as emergency 
stop control devices and safety mats (SMS from Schmersal).

The safety function is defined as the opening of the enabling circuits 
13-14, 23-24 and 33-34 when the inputs S13-S14 and/or S23-S24 are 
opened. The safety-relevant current paths with the output contacts 13-14, 
23-24 and 33-34 meet the following requirements under observation of a 
PFH value assessment (also refer to chapter 2.5 "Safety classification"):  
– Control category 4 – PL e to DIN EN ISO 13849-1  
– Corresponds to SIL 3 to DIN EN 61508-2  
– SILCL 3 to DIN EN 62061

To determine the Performance Level (PL) of the entire safety function 
(e.g. sensor, logic, actuator) to DIN EN ISO 13849-1, an analysis of all 
relevant components is required.

2.4  Technical data
General data: 

Standards:

 

IEC/EN 60204-1, EN 60947-5-1;  

EN ISO 13849-1, IEC 61508

Climate resistance:

  

EN 60068-2-78

Mounting:  

Snaps onto standard DIN rail to EN 60715

Terminal designations:

  

EN 60947-1

Material of the housings:

 

Plastic, glass-fibre reinforced 

 thermoplastic, ventilated

Material of the contacts:

 

AgSnO, self-cleaning, positive drive

Weight:

 

24 V-version: 320 g,  

230 V-version: 340 g

Start conditions:

 

Automatic or start button

Feedback circuit (Y/N):

 yes

Pull-in delay:

 

typ. 200 ms, max. 400 ms

Drop-out delay in case of  

 

emergency stop:

 

typ. 20 ms, max. 25 ms

Drop-out delay on "supply failure":

 

typ. 100 ms

Bridging in case of voltage drops:

 

typ. 90 ms 

Mechanical data: 

Connection type:

 

Screw connection

Cable section:

 

Min. 0.25 mm² / max. 2.5 mm²

Connecting cable:

  

rigid or flexible

Tightening torque for the terminals:

  

0.6 Nm

With removable terminals (Y/N):

 yes

Mechanical life: 

10 million operations

Electrical life:  

Derating curve available on request

Resistance to shock:

 

10 g / 11 ms

Resistance to vibrations to EN 60068-2-6: 

10 ... 55 Hz,  

amplitude 0.35 mm

Ambient conditions: 

Ambient temperature:

 

– 25 °C … +60 °C

Storage and transport temperature:

 

– 40 °C … +85 °C

Protection class: 

Enclosure: IP40  

Terminals: IP20  

Clearance: IP54

Air clearances and creepage  

 

distances to IEC/EN 60664-1:

 

4 kV/2 (basic insulation)

EMC rating:  

to EMC Directive

Electrical data: 

Contact resistance in new state:

 

max. 100 mΩ

Power consumption: 

 

- 24V-version: 

 

max. 1.6 W / 3.7 VA 

- 230V-version: 

 

max. 2.0 W / 5.1 VA

Rated operating voltage U

e

:

 

 

- 24V-version:

 

24 VDC –15% / +20%,  

residual ripple max. 10% 

24 VAC –15% / +10%,  

- 230V-version:

 

48 … 240 VAC

Frequency range: 

50 / 60 Hz

Fuse rating for the operating voltage: 

 

- 24V-version:

 

F1: internal electronic fuse,  

tripping current > 500 mA;  

secondary side: internal electronic fuse,  

tripping current > 0.12 A;  

- 230V-version: 

primary side: safety fuse, tripping current T 1 A

Monitored inputs: 

Cross-wire detection (Y/N):  

Yes

Wire breakage detection (Y/N):  

Yes

Earth leakage detection (Y/N):  

Yes

Number of NO contacts:

 0

Number of NC contacts:

 2

Cable length: 

1,500 m mit 1.5 mm² 
2,500 m mit 2.5 mm²

Conduction resistance:

 

max. 40 Ω

Outputs: 

Number of safety contacts:

 3

Number of auxiliary contacts: 

1

Number of signalling outputs:  

0