4
Operating instructions
Safety light curtain/safety light grid
SLC 420
SLG 420
EN
2.6 Response time (reaction time)
The response time depends on the hight of the protection field, the
resolution, the number of light beams and the beam coding
SLC 420 Resolution 14 mm
Pro-
tection
field
height
[mm]
Beams
[Number]
Res-
ponse
time
[ms]
Response
time with
beam coding
A
[ms]
Weight
Standard
[kg]
Weight
IP69K
[kg]
170
16
10
15
09
16
250
24
10
15
12
19
330
32
10
15
15
23
410
40
10
15
18
26
490
48
10
15
20
30
570
56
20
27
23
33
650
64
20
27
25
37
730
72
20
27
28
41
810
80
20
27
31
45
890
88
20
27
34
48
970
96
20
27
36
52
1050
104
20
27
39
56
1130
112
20
27
42
60
1210
120
20
27
45
64
1290
128
20
27
47
68
1370
136
20
27
50
72
1450
144
20
27
52
76
SLC 420 Resolution 30 mm
Pro-
tection
field
height
[mm]
Beams
[Number]
Res-
ponse
time
[ms]
Response
time with
beam coding
A
[ms]
Weight
Standard
[kg]
Weight
IP69K
[kg]
170
8
10
15
09
16
250
12
10
15
12
19
330
16
10
15
15
23
410
20
10
15
18
26
490
24
10
15
20
30
570
28
10
15
23
33
650
32
10
15
25
37
730
36
10
15
28
41
810
40
10
15
31
45
890
44
10
15
34
48
970
48
10
15
36
52
1050
52
20
27
39
56
1130
56
20
27
42
60
1210
60
20
27
45
64
1290
64
20
27
47
68
1370
68
20
27
50
72
1450
72
20
27
52
76
1530
76
20
27
55
---
1610
80
20
27
58
---
1690
84
20
27
61
---
1770
88
20
27
63
---
SLC 420 Resolution 50 mm
Protection
field height
[mm]
Beams
[Number]
Response
time
[ms]
Response time with
Beam coding A
[ms]
Weight
[kg]
170
4
10
15
09
250
6
10
15
12
330
8
10
15
15
410
10
10
15
18
490
12
10
15
20
570
14
10
15
23
650
16
10
15
25
730
18
10
15
28
810
20
10
15
31
890
22
10
15
34
970
24
10
15
36
1050
26
10
15
39
1130
28
10
15
42
1210
30
10
15
45
1290
32
10
15
47
1370
34
10
15
50
1450
36
10
15
52
1530
38
10
15
55
1610
40
10
15
58
1690
42
10
15
61
1770
44
10
15
63
SLG 420
Beams
[Number]
Beam
dis-
tance
[mm]
Res-
ponse
time
[ms]
Response time
with beam
coding A
[ms]
Weight
Standard
[kg]
Weight
IP69K
[kg]
2
500
10
15
25
37
3
400
10
15
35
51
4
300
10
15
36
52
2.7 Effective resolution
The effective resolution in case of activated blanking of floating beams
can be found in the following table:
Blanked beams
Physical resolution Effective resolution
1
14
24
2
14
34
3
14
44
4
14
54
Blanked beams
Physical resolution Effective resolution
1
30
48
2
30
68
3
30
88
4
30
108
Blanked beams
Physical resolution Effective resolution
1
50
88
2
50
128
3
50
168
4
50
208