Operating instructions

Passive fieldbox

PFB-SD-4M12-SD

EN

1.6  Warning about misuse

In the event of improper or unintended use or tampering, use 

of the passive fieldbox could expose persons to danger or 

cause damage to the machine or system components.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden; the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

PFB-SD-4M12-SD
Option

Description

PFB

Passive fieldbox

SD

Evaluation side: SD interface

4M12

4 device connectors for M12 connector

SD

Device connection: SD interface

2.2  Destination and use

The passive fieldbox PFB-SD-4M12-SD is designed for the connection 

of 4 electronic safety relays in SD interface version of the manufacturer 

SCHMERSAL. It serves to connect up to 4 safety switchgear units in 

series.

In order to increase the safety function, it is possible to connect multiple 

passive fieldboxes in series.

The secure OSSD outputs of the connected safety relays are switched 

in series and wired to a compatible security analysis by the passive 

fieldbox PFB-SD-4M 12-SD.

The non-secure SD interface signals of the devices are connected in 

series and wired to an SD Gateway.

The user must evaluate and design the safety chain in 

accordance with the relevant standards and the required 

safety level.

2.3  Technical data

Standards:

 

IEC 60947-1

Materials: 

 

- Enclosure:

 

polyamide / PA 6 GF 

- Inspection window:

 

polyamide / PACM 12 

- Encapsulation:

 

polyurethane / 2K PU 

- Labelling plates:

 

polycarbonate / PC

Mechanical data 

Type of electrical connection:

 

Panel jack / integrated socket

Connection: 

 

- Connectors:

 

M12 / 8-pole, A-coded 

- Power:

 

M12-Power / 4-pole, T-coded 

- IN & OUT signals:

 

M12 / 4-pole, A-coded

Tightening torque of connectors: 

 

- M12 connector:

 

max. 1.5 Nm 

- Recommended for SCHMERSAL cables:

 

1.0 Nm

Fixing screws:

 

2x M6

Tightening torque of the fixing screws:

 

max. 3.0 Nm

Ambient conditions 

Ambient temperature:

 

−20 °C … +65 °C

Storage and transport temperature:

 

−25 °C … +70 °C

Relative humidity:

 

10 % … 95 %, non condensing

Resistance to shock:

 

30 g / 11 ms

Resistance to vibration:

 

5 … 10 Hz, amplitude 3.5 mm; 

 

10 … 150 Hz, amplitude 0.35 mm / 5 g

Protection class:

 

IP67 to IEC 60529

Protection class:

 III

Insulation values to IEC 60664-1: 

 

- Rated insulation voltage Ui:

 

32 VDC 

- Rated impulse withstand voltage U

imp

:

 

0.8 kV 

- Over-voltage category:

 III 

- Degree of pollution:

 3

Electrical data 

Supply voltage U

B

:

 

24 VDC -15% / +10% 

 

(stabilised PELV mains unit)

Rated operating voltage U

e

 

24 VDC

Operating current I

e

 

- Fieldbox (external fuse protection required):

 

10 A 

- Derating M12 Power connector:

 

10 A to 55 °C

 

7 A to 65 °C

 

- Device connection:

 

0.8 A 

 

(internal protection available) 

 

- Safety outputs Y1 and Y2:

 

0.1 A

Device connection line fuse:

 

Automatically resetting  

fuse element 1.5 A

LED indications 

1 green LED „Pwr“:

 

Supply voltage fieldbox

4 green LED "P":

 

Fuse-element device connection 1 - 4

4 yellow LED "I“:

 

Input safety enable device connection 1 - 4

Protection class IP67 is only reached if all M12 connectors 

and blanking plugs, as well as the inspection window are 

properly fastening with screws.

All fieldboxes have a good resistance against chemicals 

and oil. When used in aggressive media (.e.g chemicals, 

oils, lubricants and coolants in high concentrations) the 

material resistance must in each case be checked in 

advance for the specific application.

Содержание PFB-SD-4M12-SD

Страница 1: ...e passive fieldbox must only be used according to the following versions or for applications that are approved by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual the country specific installation standards as w...

Страница 2: ...ith the relevant standards and the required safety level 2 3 Technical data Standards IEC 60947 1 Materials Enclosure polyamide PA 6 GF Inspection window polyamide PACM 12 Encapsulation polyurethane 2K PU Labelling plates polycarbonate PC Mechanical data Type of electrical connection Panel jack integrated socket Connection Connectors M12 8 pole A coded Power M12 Power 4 pole T coded IN OUT signals...

Страница 3: ...rs 101217788 2 5 m Connecting cable male female connectors 101217789 3 5 m Connecting cable male female connectors 103013428 5 0 m Connecting cable male female connectors 101217790 7 5 m Connecting cable male female connectors 103013429 3 3 2 Colour codes of the Schmersal cables M12 4 pole M12 8 pole PIN Conductor colour PIN Conductor colour 1 BN Brown 1 WH White 2 WH White 2 BN Brown 3 BU Blue 3 ...

Страница 4: ... 2 Input LED POWER LED Device connection 3 Input LED POWER LED Device connection 1 Input LED POWER LED Device connection 4 Input LED Connection Power IN Connection Power OUT Power LED fieldbox DIP switch fieldbox configuration Connection Out signals SD and safety signals Park position Jumper 2 Park position Jumper 1 Jumper fieldbox configuration Connection IN signals SD and safety signals ...

Страница 5: ...nd 7 8 set Switch 1 2 and 7 8 ON The sealing labels available as an accessory can be used to seal the inspection window after the configuration has been checked 4 5 Connector configuration 4 5 1 Connector configuration of device connection PIN Colour Signal Description of device signals 1 WH A1 24 VDC device supplied 2 BN X1 Safety input 1 3 GN A2 0 VDC device supply 4 YE Y1 Safety output 1 5 GY O...

Страница 6: ...DC 10A SD Out 0 VDC 24 VDC SD Out SD In FB 2 3 1 4 I O Power 2 1 3 4 I O SD O N 1 8 7 6 5 4 3 2 BK 4 BN 1 WH 2 WH 2 BU 3 BK 4 BU 3 BN 1 PLC Power supply Safety monitoring module Safety switchgear Fieldbox in the centre JP SW 7 8 OFF 4 devices connected JP SW 1 6 OFF SD Gateway Terminals Optional additional SD line ...

Страница 7: ...ive fieldbox EN I O Power 2 1 3 4 I O SD I O Power 2 1 3 4 I O SD O N 1 8 7 6 5 4 3 2 2 1 2 3 1 O N 1 8 7 6 5 4 3 2 Last fieldbox JP SW 7 8 ON 3 devices connected JP SW 5 6 ON Fieldbox in the centre JP SW 7 8 OFF 2 devices connected JP SW 3 4 ON ...

Страница 8: ...ly wiring and 10 A fuse protection Use of SCHMERSAL cables The cable lengths listed in the table between power supply and the 1st field box and between fieldboxes are maximum lengths Reducing the individual cable lengths is not critical Device configuration version Max number of devices Equals number of fieldboxes Length of the cable A up to the 1st fieldbox Length of the cables B between the fiel...

Отзывы: