Mounting

In hygiene-sensitive applications, the assembly housing must 

be fitted with an offset angle of at least 3 in order to ensure 

that water and other liquids can run off.

Assembly must be carried out on a grease-free, level 

surface with suitable M5 cheese-head screws and a sealing 

element to ensure a protection class up to IP69K. In hygiene 

applications, it must be ensured that cleaning and inspection 

for damage can be carried out from all sides. As such, we 

recommend a clearance of at least 10 cm to other machine 

parts.

Enclosure for surface mounting

B

D

E

A

C

Tightening torque for the M5 fixing screws in the enclosure 

lower section 2 Nm ± 0.1 Nm.

Key

A:

Cover fixing screws with gasket

B:

Enclosure cover 

C:

Cover gasket

D:

Enclosure lower section

E:

Floor seal

Supply kit

A:  Supply kit with 8x cover 

fixing screws with gasket

C:  Earth connection supply kit 

comprising 6x washers,  

3x serrated lock washers and 3x nuts

Tightening torque 1,3 Nm ± 0,1 Nm

Maintenance

Only approved cleaning agents are permitted for cleaning. 

We would be happy to provide a list on request. Cleaning 

must not be carried out above 80 °C. After cleaning, an 

inspection must be carried out from all sides to check for 

damage. Faulty devices/parts must be replaced immediately.