2
Operating instructions
Enclosure for surface mounting
NBGLC5…
NBGLC5…NSK
EN
K.A. Schmersal GmbH & Co. KG
Möddinghofe 30, 42279 Wuppertal
Germany
Phone: +49 202 6474-0
Telefax: +49 202 6474-100
E-Mail: [email protected]
Internet: www.schmersal.com
Mounting
In hygiene-sensitive applications, the assembly housing must
be fitted with an offset angle of at least 3 in order to ensure
that water and other liquids can run off.
Assembly must be carried out on a grease-free, level
surface with suitable M5 cheese-head screws and a sealing
element to ensure a protection class up to IP69K. In hygiene
applications, it must be ensured that cleaning and inspection
for damage can be carried out from all sides. As such, we
recommend a clearance of at least 10 cm to other machine
parts.
Enclosure for surface mounting
B
D
E
A
C
Tightening torque for the M5 fixing screws in the enclosure
lower section 2 Nm ± 0.1 Nm.
Key
A:
Cover fixing screws with gasket
B:
Enclosure cover
C:
Cover gasket
D:
Enclosure lower section
E:
Floor seal
Supply kit
A: Supply kit with 8x cover
fixing screws with gasket
C: Earth connection supply kit
comprising 6x washers,
3x serrated lock washers and 3x nuts
Tightening torque 1,3 Nm ± 0,1 Nm
Maintenance
Only approved cleaning agents are permitted for cleaning.
We would be happy to provide a list on request. Cleaning
must not be carried out above 80 °C. After cleaning, an
inspection must be carried out from all sides to check for
damage. Faulty devices/parts must be replaced immediately.