background image

7

G50/150

G50-2047

Operating instructions

Gear-switch and safety gear-switch

EN

G50_150-C-EN

8. EU Declaration of conformity

Place and date of issue:

Wuppertal, 10  February 01, 2016

Authorised signature

Philip Schmersal

Managing Director

EU Declaration of conformity

Original

K.A. Schmersal GmbH & Co. KG

Möddinghofe 30

42279 Wuppertal

Germany

Internet: www.schmersal.com

We hereby certify that the hereafter described components both in their basic design and construction conform 

to the applicable European Directives. 

Name of the component:

G50, G150,  

G50-2047

Type:

See ordering code

Description of the component:

Gear switch

Relevant Directives:

Valid up to  

April 19, 2016

Valid as of  

April 20, 2016

Machinery Directive 

1)

Low Voltage Directive 

2)

RoHS-Directive

2006/42/EC

2006/95/EC

2011/65/EU

2006/42/EC

2014/35/EU

2011/65/EU

Affixing of the CE conformity mark:

1)

  for safety components, whose type plate is 

labelled "safety component"

2)

 for gear switches without safety function

Applied standards:

DIN EN 60947-5-1: 2010,

DIN 56950-1: 2012 

1)

Person authorised for the compilation  

of the technical documentation:

Oliver Wacker

Möddinghofe 30

42279 Wuppertal

The currently valid declaration of conformity can be  

downloaded from the internet at www.schmersal.net.

Содержание G50

Страница 1: ...ine or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufac turer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country speci...

Страница 2: ...pped immediately after the switching point and no faulty switching due to vibrations or for instance the rocking of the boom is admitted For emergency end stops microswitches of the Z 6881 11 1 series with positive break of the NC contact are available Due to the constant contact force this element is extremely resistant to vibrations even right before the snap point In order to ensure a safe swit...

Страница 3: ...45 160 145 3 3 Switching point setting During the switching point setting of the contacts contact with live parts is possible Only execute the setting when the switch lever is not on the switch curve to avoid too strong a reduction of the lifetime Always set the emergency limit switch first Standard version In the standard version the central screw of the disc cam is loosened A disc cam which can ...

Страница 4: ...Z11 T11 T01 M11 Z11 T11 T01 M11 Z11 min max G50 1 17 16 1 15 4 15 9 16 1 0 9 1 6 1 1 0 9 0 14 0 2 21 20 17 0 6 600 G50 1 25 23 6 22 8 23 4 23 6 1 4 2 2 1 6 1 4 0 2 0 3 14 40 25 0 9 600 G50 1 35 33 1 31 7 32 8 33 1 1 9 3 3 2 2 1 9 0 3 0 5 10 30 35 1 2 600 G50 1 50 47 3 45 3 46 8 47 3 2 7 4 7 3 2 2 7 0 3 0 7 7 20 50 0 7 600 G150 1 75 71 0 68 0 70 2 71 0 4 0 7 0 4 8 4 0 0 6 1 0 4 80 75 2 5 600 G150 1...

Страница 5: ... On each side maximum 1 Z 6881 11 1 switch may be in stalled in position 4 see figure Position of the emergency limit switch 5 1 Selection and setting instructions In order to ensure the safe operation of a device certain safety distanc es between the fixed surrounding parts and the moving parts must not be dropped below These safety distances are ensured by the switching points of the emergency c...

Страница 6: ...alculated value Lfixed which must be calculated depending on the hazard in accordance with the direction of movement and depending on the load condition full load or partial load It also depends on the gear of the device and its set up The displacement can be converted in degrees in the following way Y1 2 DEGREE Unutz Y1 2 y1 2 DEGREE Unutz y1 2 360 6 Set up and maintenance 6 1 Functional testing ...

Страница 7: ... the component G50 G150 G50 2047 Type See ordering code Description of the component Gear switch Relevant Directives Valid up to April 19 2016 Valid as of April 20 2016 Machinery Directive 1 Low Voltage Directive 2 RoHS Directive 2006 42 EC 2006 95 EC 2011 65 EU 2006 42 EC 2014 35 EU 2011 65 EU Affixing of the CE conformity mark 1 for safety components whose type plate is labelled safety component...

Страница 8: ... A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...

Отзывы: