Operating instructions

Safety sensor

EX-BNS 303-2187

EN

1.6  Warning about misuse

In case of improper use or manipulation of the safety 

switchgear, personal hazards or damages to machinery 

or plant components cannot be excluded. The relevant 

requirements of the standard ISO 14119 must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden; the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

EX-BNS 303-12Z

-2187-3G/D

No.

Option

Description

without LED

G

with LED

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond to 

the standard version.

2.3  Purpose

The safety sensor can be used for monitoring the position of movable 

guards and flaps in explosion-endangered areas of Zone 2 and 22 

category 3GD. The installation and maintenance requirements to the 

standard series EN 60079 must be met. To actuate the EX-BNS 303 

safety sensors, only the BPS 300, BPS 303 or BPS 303 SS actuators 

can be used.

The safety switches are used for applications, in which the hazardous 

situation is terminated without delay when the safety guard is opened.

The safety switchgears are classified according to  

ISO 14119 as type 4 interlocking devices.

Only the entire system consisting of the safety sensor (EX-BNS), the 

actuator (BPS) and the safety-monitoring module (AES/SRB/AZR) 

meets the requirements of the standard IEC 60947-5-3.

Conditions for safe operation

Due to their specific impact energy, the components must be fitted  

with a protection against mechanical stresses.

The specific ambient temperature range must be observed. The user 

must provide for a protection against the permanent influence of UV 

rays. The energy restriction for LED versions (24 V/10 mA) must be 

ensured by the user.

The user must evaluate and design the safety chain in 

accordance with the relevant standards and the required 

safety level. 

The entire concept of the control system, in which the 

safety component is integrated, must be validated to the 

relevant standards.

2.4  Technical data

Equipment category:

 

L

 II 3GD

Ex protection:

 

Ex nC IIC T6 Gc X; Ex tc IIIC T80°C Dc X

Standards:

 

IEC 60947-5-3; EN 60079-0; EN 60079-15;  

EN 60079-31; ISO 80079-36; BG-GS-ET-14

Design:

 cylindrical

Tightening torque:

 

SW 36 max. 300 Ncm

Enclosure:

 

glass-fibre reinforced thermoplastic

Max. impact energy:

 

1 J

Protection class: 

IP67 to IEC 60529

Connection:

 

Boflex cable

Cable section:

 

6 x 0.25 mm²

Operating principle:

 magnetic

Actuating magnet:

 

BPS 300 ,BPS 303,  

BPS 303 SS, coded

Assured switching distance s

ao

:

 

5 mm

Assured switch-off distance s

ar

:

 

15 mm

Coding level according to ISO 14119:

 low

Switching condition indication:

 

LED only with ordering suffix G

Switching voltage max.:

 

without LED: 100 VAC / DC 

with LED: 24 VDC

Switching current max.:

 

without LED: 400 mA 

with LED: 10 mA

Switching capacity max.:

 

without LED: 10 W 

with LED: 240 mW

Ambient temperature: 

 

−25 °C ... +70 °C

Storage and transport temperature:

 

−25 °C ... +70 °C

Max. switching frequency:

 

5 Hz

Resistance to shock:

 

30 g / 11 ms

Resistance to vibration:

 

10 ... 55 Hz, amplitude 1 mm

2.5  Safety classification

Standards: 

ISO 13849-1

B

10D

 (NC/NO contact): 

25,000,000  

at max. 20 % contact load

Service life: 

20 years

MTTF

B

d x

x

h

s/h

3600

D

10D

op

op

op

n

0,1 x n

op

t

cycle

(Specifications can vary depending on the application-specific 

parameters h

op

, d

op

 and t

cycle

 as well as the load.)

An individual switch can be used in a category 3 or 4 architecture  

up to PL e. 

If multiple safety components are wired in series, the Performance 

Level to ISO 13849-1 will be reduced due to the restricted error 

detection under certain circumstances.