1.6  Warning about misuse

In case of improper use or manipulation of the safety switch-

gear, personal hazards or damages to machinery or plant 

components cannot be excluded when safety switchgear is 

used. The relevant requirements of the standard ISO 14119 

must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages resul-

ting from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary re-

pairs, conversions and modifications to the device are strictly forbidden; 

the manufacturer shall accept no liability for damages resulting from 

such invasive work, arbitrary repairs, conversions and/or modifications 

to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

BNS 36-

➀➁

Z

-

-

-

No.

Option

Description

Safety contacts:

11

1 NO / 1 NC

02

2 NC

Signalling contacts:

No signalling contact

/01

1 NC

Without LED

G

With LED

connecting cable

ST

Connector plug M 8

L

Left hinged door

R

Right hinged door

2750

Version with extended switching distance  

(in combination with actuator) 

BPS 36-1-2750 or BPS 36-2-2750)

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond to 

the standard version.

2.3  Destination and use

The BNS 36 safety sensor is designed for application in safety circuits 

and is used for monitoring the position of movable safety guards to  

ISO 14119 and IEC 60947-5-3. To actuate the safety sensors, only the 

BPS 36-1 (-2750) or BPS 260-2 (-2750) actuators can be used.

The safety sensors are used for applications, in which the hazardous 

situation is terminated without delay when the safety guard is opened.

The safety switchgears are classified according to  

ISO 14119 as type 4 switching devices. 

Only the entire system consisting of the safety sensor (BNS 36), the 

actuator (BPS 36) and the safety-monitoring module (AES, SRB) meets 

the requirements of the standard IEC 60947-5-3.

The user must evaluate and design the safety chain in 

accordance with the relevant standards and the required 

safety level.

The entire concept of the control system, in which the safety 

component is integrated, must be validated to the relevant 

standards.

2.4  Technical data

Standards: 

IEC 60947-5-3, BG-GS-ET-14

Enclosure:

 

glass-fibre reinforced thermoplastic

Protection class:

 

IP67 to IEC 60529

Connection:

 

Connecting cable LIYY  

or connector plug M8

Cable section of connecting cable:

 

 

- without signalling contact:

 

4 x 0.25 mm² 

- with signalling contact:

 

6 x 0.25 mm²

Version with integrated connector:

 

 

- without signalling contact:

 

M8 x 1, 4-pole, with screw terminal  

or snap fitting 

- with signalling contact:

 

8 mm, 6-pole, with snap fitting

Tightening torque for connectors:

 

max. 0.3 Nm

Operating principle:

 magnetic

Actuator:

 

BPS 36-1 (-2750), BPS 36-2 (-2750),  

coded

Coding level according to ISO 14119:  

low

Switching distances: 

 

- Assured switching distance s

ao

:

 

7 mm,  

10 mm (ordering suffix -2750) 

- Assured switch-off distance s

ar

:

 

17 mm,  

20 mm (ordering suffix -2750)

Switching condition indication:

 

LED only with ordering suffix G

Rated insulation voltage U

i

 

- without LED: 

50 VAC / 75 VDC 

- with LED:

 

75 VDC

Rated impulse withstand voltage U

imp

0.8 kV

Switching voltage: 

 

- without LED: 

max. 75 VDC 

- with LED:

 

max. 24 VDC 

- with 6-pole connector:

 

max. 30 V

Switching current: 

 

- without LED: 

max. 400 mA 

- with LED:

 

max. 10 mA

Switching capacity: 

  

- without LED: 

max. 10 W 

- with LED:

 

max. 240 mW

Required short-circuit current: 

100 A

Ambient temperature:

 

−25 °C ... +70 °C

Storage and transport temperature:

 

−25 °C ... +70 °C

Max. switching frequency:

 

5 Hz

Resistance to shock:

 

30 g / 11 ms

Resistance to vibration:

 

10 ... 55 Hz, amplitude 1 mm

2.5  Safety classification

Standards:

 

ISO 13849-1

Safety contact: 

 

- NC / NC combination: 

S11-S12 and S21-S22 

- NC / NO combination: 

S21-S22 and S13-S14

Intended structure:  

 

- 2-channel usage: 

usable to cat. 4 / PL e  

with suitable logic unit

B

10d

 NC contacts at 20 % contact load: 

25.000.000

B

10d

 NO contacts at 20 % contact load: 

25.000.000

Service life:

 

20 years

MTTF

B

d x

x

h

s/h

3600

D

10D

op

op

op

n

0,1 x n

op

t

cycle

(Determined values can vary depending on the application-specific 

parameters h

op

, d

op

 and t

cycle

 as well as the load.)

If multiple safety components are wired in series, the Performance Le-

vel to ISO 13849-1 will be reduced due to the restricted error detection 

under certain circumstances.