background image

1

BN 325-R(G)

Operating instructions

Magnetic reed switches

EN

1.  About this document

1.1  Function

This operating instructions manual provides all the information 

required for the mounting, set-up and commissioning to ensure the 

safe operation and disassembly of the safety switchgear. the operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The product must be exclusively used in accordance with the versions 

listed below or for the applications authorised by the manufacturer. 

Detailed information regarding the range of applications can be found in 

the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating 

instructions manual, the country specific installation standards as well 

as all prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

1.6  Warning about misuse

In case of inadequate or improper use or manipulations of 

the component, personal hazards or damage to machinery 

or plant components cannot be excluded.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 

defective mounting or failure to comply with this operating instructions 

manual. The manufacturer shall accept no liability for damages 

resulting from the use of unauthorised spare parts or accessories.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2  Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Purpose  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

3.3  Mounting set-up and actuating distances  . . . . . . . . . . . . . . . . . . . .3

4  Rear side Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .3

4.2  Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

5  Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

6  Disassembly and disposal

6.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

6.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

7  EU Declaration of conformity

x.000 / 1

1.2017 / v

.A.   -   101

135689-EN / H / 2017-1

1-14 / 

AE-Nr

. 8380

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 4

Original

Содержание BN 325-R

Страница 1: ...uctions in this operating instructions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention rules Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet www schmersal net The information contained in this operating instructions manual is provided without liability and is su...

Страница 2: ... magnet the switching distances and travels may vary 2 4 Technical data Standards Enclosure and cover glass fibre reinforced thermoplastic Protection class Ordering suffix 1239 and 1389 IP00 Ordering suffix 1279 and 1297 2 IP67 Termination Ordering suffix 1239 Blade terminal 4 8 mm Ordering suffix 1389 Blade terminal 6 3 mm Ordering suffix 1279 and 1279 2 Cable outlet Ordering suffix LST 1279 Cabl...

Страница 3: ...279 BU BN PIN 3 PIN 4 PIN 1 BN 325 RG 1279 BN 325 RG 1279 2 BK BU BN BN BU BK 3 2 1 4 Inductive loads e g contactors relays etc are to be provided with suitable interference suppression circuitry 4 2 Adjustment In order to actuate the BN 325 R RG magnetic switch a north or south pole magnet should be used The markings found on the actuating side of the cover are used for adjusting the magnet to th...

Страница 4: ...42279 Wuppertal Germany Internet www schmersal com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives Name of the component BN 1 BN 2 BN 3 BN 6 BN 7 BN 8 Description of the component Magnetic reed switches Relevant Directives Low Voltage Directive RoHS Directive 2014 35 EU 2011 65 EU K A Schmersal GmbH...

Отзывы: