background image

2

Operating instructions

Magnetic reed switches

BN 325-R(G)

EN

For safety reasons, invasive work on the device as well as arbitrary 

repairs, conversions and modifications to the device are strictly 

forbidden; the manufacturer shall accept no liability for damages 

resulting from such invasive work, arbitrary repairs, conversions and/or 

modifications to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

BN 325-R

-

No.

Option

Description

without LED

G

with LED

Blade terminal 4,8 mm and 1 shielding plate

1239

Blade terminal 4,8 mm and 2 shielding plates

1389

Blade terminal 6,3 mm and 2 shielding plates

1279

Cable outlet left and 2 shielding plates

1279-2

Cable outlet right and 2 shielding plates

LST-1279

Cable with connector, -1279 like above

Only if the information described in this operating instructions 

manual are realised correctly, the compliance with the Low 

Voltage Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 

these specifications apply accordingly, provided that they correspond to 

the standard version.

2.3  Purpose

Magnetic switches are preferably used wherever mechanically operated 

limit switches do not feature a satisfactory operation due to the 

unfavourable operating conditions. In the elevator industry, magnetic 

switches are preferably used for positioning and control purposes.

For actuating the magnetic swtches, the actuating magnets listed 

by Schmersal (refer to Automation technology catalogue) can be 

used. Depending on the chosen combination of magnetic switch and 

actuating magnet, the switching distances and travels may vary. 

2.4  Technical data

Standards:

 

Enclosure and cover:

 

glass-fibre reinforced thermoplastic

Protection class: 

 

- Ordering suffix -1239 and -1389:

 IP00

 

- Ordering suffix -1279 and -1297-2:

 IP67

Termination: 

 

- Ordering suffix -1239:

 

Blade terminal 4.8 mm 

- Ordering suffix -1389:

 

Blade terminal 6.3 mm 

- Ordering suffix -1279 and -1279-2:

 

Cable outlet 

- Ordering suffix -LST-1279:

 

Cable with connector

Operating principle: 

magnetic

Switching voltage: 

max. 250 VAC

Switching current: 

max. 3 A

Switching capacity: 

max. 120 VA

Sparkover voltage: 

> 600 VAC (50 Hz)

Switching speed: 

max. 18 m/s

Switching frequency: 

max. 300 /s

Switching time “Close“: 

max. 1.5 ms

Switching time “Open”: 

max. 0.5 ms

Bounce duration: 

0.3 ... 0.6 ms 

Ambient temperature: 

– 25 °C … + 75 ºC

Mechanical life: 

1 billion operations

Electrical life: 

1 million - 1 billion operations,  

depending on load

Resistance to shock: 

50 g / 11 ms

Resistance to vibration: 

30 g on sine wave oscillation

Resistance to vibration: 

10 ... 55 Hz, amplitude 1 mm

Switching point accuracy: 

± 0.25 mm, T = constant

3.  Mounting

3.1  General mounting instructions

The installation may only be carried out by authorised 

 personnel.

• Any mounting position.

•  Do not install the magnetic switch and the actuating magnet in strong 

magnetic fields

•  Keep away from metal chips

•  Do not expose the magnetic switch and the actuating magnet to 

strong vibrations and heavy shocks

•  Do not use the magnetic switch and the actuating magnet as end stop

•  The mounting distance between two sensors should always be at 

least 30 mm.

When using more than one magnet switch, consider figures 

next page.

3.2  Dimensions

All measurements in mm.

 Blade  terminal

8

26

10

8

(9)

24

10

85

30

9

M 4

a

b

b

PIN 2

PIN 1

 Cable  outlet

9,8

9

9

ø 9

M 4

a

a

c

c

d

d

LED

13

LED

Key

a  Shielding plate

b   Blade  terminal

c   Cable outlet left (Index -1279)

d   Cable outlet right (Index -1279-2)

Содержание BN 325-R

Страница 1: ...uctions in this operating instructions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention rules Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet www schmersal net The information contained in this operating instructions manual is provided without liability and is su...

Страница 2: ... magnet the switching distances and travels may vary 2 4 Technical data Standards Enclosure and cover glass fibre reinforced thermoplastic Protection class Ordering suffix 1239 and 1389 IP00 Ordering suffix 1279 and 1297 2 IP67 Termination Ordering suffix 1239 Blade terminal 4 8 mm Ordering suffix 1389 Blade terminal 6 3 mm Ordering suffix 1279 and 1279 2 Cable outlet Ordering suffix LST 1279 Cabl...

Страница 3: ...279 BU BN PIN 3 PIN 4 PIN 1 BN 325 RG 1279 BN 325 RG 1279 2 BK BU BN BN BU BK 3 2 1 4 Inductive loads e g contactors relays etc are to be provided with suitable interference suppression circuitry 4 2 Adjustment In order to actuate the BN 325 R RG magnetic switch a north or south pole magnet should be used The markings found on the actuating side of the cover are used for adjusting the magnet to th...

Страница 4: ...42279 Wuppertal Germany Internet www schmersal com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives Name of the component BN 1 BN 2 BN 3 BN 6 BN 7 BN 8 Description of the component Magnetic reed switches Relevant Directives Low Voltage Directive RoHS Directive 2014 35 EU 2011 65 EU K A Schmersal GmbH...

Отзывы: