Leakage current I
r
, maximum
0.5 mA
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.25 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.25 A
Test pulse duration, maximum
0.5 ms
Test pulse interval, typical
1000 ms
Classification ZVEI CB24I, Source
C2
Classification ZVEI CB24I, Sink
C1
C2
Electrical data - Diagnostic outputs
Designation, Diagnostic outputs
OUT
Voltage drop U
d
, maximum
2 V
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.05 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.05 A
Status indication
Note (LED switching conditions display)
Operating condition: LED green
Error / functional defect: LED red
Supply voltage UB: LED green
Pin assignment
PIN 1
A1 Supply voltage UB
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT Diagnostic output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
IN Solenoid control
Note about the safety classification
2
The safety consideration of the guard locking function only applies for standard devices with monitored solenoid interlock
AZM300Z-…-1P2P-… (see Ordering code). A safety assessment of the guard locking function for devices with serial diagnostics
"SD2P" is not allowed due to the non-safe locking/unlocking signal from the SD Gateway.