5
AZM 200 AS
Operating instructions
Solenoid interlock
EN
6.2 Diagnostic information
Table 1: the diagnostic function of the AZM 200 AS solenoid interlock
System condition
Solenoid control (DO 0) LED
Condition
Power to
unlock
Power to
lock
green-red
3)
red
yellow
AS-i SaW-Code
(DI 0 ... DI 3)
Door open
1 (0)
0 (1)
green
Off
Off
static 0
Door closed,
actuator not inserted
1 (0)
0 (1)
green
Off
Off
static 0
Door closed,
actuator inserted
(not locked)
1
0
green
Off
Flashes
AZM 200 ST-T-AS
AZM 200 B ST-T-AS
AZM 200 BZ ST-T-AS
static 0
dynamically
DI 0, DI 1: dynamic
DI 2, DI 3: static 0
Door closed, actuator
inserted and locked
0
1
green
Off
On
dynamically
Error warning
1)
,
actuator inserted and locked.
Shutdown approaching
0
1
green
flashes
2)
/ on
On
dynamically
Error
0 (1)
1 (0)
green
Flashes
2)
Off
static 0
Internal error
0 (1)
1 (0)
green
On
Off
static 0
AS-i error: slave address = 0
or communication error
1 (0)
0 (1)
red
depending
on the
condition
depending
on the
condition
static 0
1) after 30 min -> fault
2) refer to flash code
3) AS-i Duo-LED green/red
Table 2: Error messages / flash codes red LED
Flash codes (red)
Designation
Autonomous
switch-off after
Error cause
4 flash pulses
Excess device temperature
max. 30 min
Internal excess temperature
5 flash pulses
Actuator fault
0 min
incorrect or defective actuator
6 flash pulses
Error actuator combination
0 min
An invalid combination of actuators was detected
(blocking bolt detection or tamper attempt)
Continuous red signal
Internal error
0 min
Device defective
5.5 Status signal "safety release"
The "safety release" status signal from a Safety at Work slave can be
cyclically queried by the control system through the AS-i master. To that
effect, the 4 input bits with the varying SaW code of a Safety at Work
slave are evaluated through an OR operation with 4 inputs in the control
system.
6. Diagnostic
6.1 LED display
The solenoid interlock signals the operational state as well as errors
through three coloured LED’s installed on the front side of the device.
The LED's have the following meaning (to EN 62026-2):
LED red/green
(AS-i duo LED):
AS-Interface supply voltage /
AS-Interface communication error
or slave address = 0
Red LED:
Internal device error
Yellow LED:
Device status
40
220
155,5
5
6,5
32,5
7,5
20 1
±
50
15,5
M12
38
3,3
AS-i
Fault
Status
Error
Errors, which no longer guarantee the function of the AZM 200 AS
solenoid interlock (internal error)s cause the safety outputs to be
disabled within the risk time. Any error that does not immediately affect
the safe functionality of the AZM 200 AS (e.g. the ambient temperature
too high) will lead to a delayed shut-down (refer to table 2). After fault
rectification, the error message can be reset by opening and closing
the relevant guard door. The safety outputs of the safety monitor can be
switched back on, thus enabling the machine.
Error warning
If a fault has occured, which still guarantees the function of the
AZM 200 AS solenoid interlock, the system is safely switched off after
30 minutes. The safety outputs of the safety monitor initially remain
enabled. The error message can be read out through the parameter
port (refer to Table 1). Depending on the type of fault, the machine is
not immediately shut down. The control system obtains a preliminary
message, which can be used to shutdown the process in a controlled
manner. An error warning is deleted/reset as soon as the error cause
is eliminated.