background image

3

AZM 200 AS

Operating instructions

Solenoid interlock

EN

Electrical data - AS-Interface 

AS-i supply voltage:

 

26.5 ... 31.6 VDC,  

protection against polarity reversal

AS-i power consumption:

 

≤ 100 mA

AS-i device insulation:

 

internal short-circuit proof

AS-i specification: 

 

- Version:

 

V 2.1 

- Profile:

 S-7.B.F.E

AS-i inputs: 

 

- Channel 1:

 

Data bits DI 0/DI 1 = dynamic code transmission 

- Channel 2:

 

Data bits DI 2/DI 3 = dynamic code transmission

AS-i outputs: 

 

- DO 0:

 

magnet control 

- DO 1 ... DO 3:

 

no Function

AS-i Parameter bits:  

 

- P0:

 

Safety guard and actuator detected 

- P1:

 

Solenoid interlock locked 

- P2:

 

Magnet voltage in tolerance range 

- P3:

 

Internal device error

Parameter request:

 

 default value parameter request "1111" (0xF)

AS-i Input module address:

 0 

- preset to address 0, can be changed through  

AS-interface bus master or hand-held programming device

Electrical data - auxiliary voltage AUX 

Supply voltage U

B

:

 

24 VDC (−15 % / +10 %) 

 

stabilised PELV mains unit

Power consumption:

 

≤ 500 mA

Magnet switch-on time:  

100 %

Device fuse rating:

 

≤ 4 A (when used to UL 508)

LED switching conditions display 

(1) LED green-red (AS-i Duo LED):

 

Supply voltage /  

Communication error /  

Slave address = 0

(2) LED red:

 

Internal device error

(3) LED yellow:

 

Device condition (Enabling status)

Use isolated power supply only.  

For use in NFPA 79 applications only.  

Adapters providing field wiring means are available from  

the manufacturer. Refer to manufacturers information.

2.5  Safety classification of the interlocking function

Standards:

 

ISO 13849-1, IEC 61508

PL:

 e

Control Category:

 4

PFH:

 

4 x 10

-9

 / h

SIL:

 

suitable for SIL 3 applications 

Mission time: 

20 years

2.6  Safety classification of the guard locking function

If the device is used as an interlock for personal safety, a safety 

classification of the guard locking function is required.

When classifying the guard locking function, a distinction must be 

made between monitoring of the interlocking function and control of the 

release function.

The following classification of the release function is based on the prin-

ciple of isolating the supply of power to the solenoid.

The safety classification for the release function only applies 

to devices with monitored interlock function, in power to 

unlock version and with solenoid supply from 24 VDC (AUX) 

(see ordering code).

By reliably isolating the power externally, it can be assumed that no 

errors can occur with regard to actuation of the release function. In that 

case, the device does not contribute towards the failure probability of 

the release function.

The level of safety of the release function relies, therefore, exclusively 

on reliable external deactivation of the power. 

AUX + 

AUX - 

+24 VDC

0 VDC

PL ?
PFH

D

?

 

Safety power 
shutdown

Solenoid 
interlock

Guard locking 
function

To simplify classification of the release function, the following 

parameters can be assumed for the device:

PL:

 e

Control Category:

 4

PFH:

 

≤ 1.00 x 10

-9

 / h

SIL:

 

suitable for SIL 3 applications

Mission time:

 

20 years

Fault exclusion with regard to wiring routing must  

be observed.

If for a certain application the power to unlock version of 

a solenoid interlock cannot be used, for this exception 

an interlock with power to lock can be used if additional 

safety measure need to be realised that have an 

equivalent safety level.

3.  Mounting

3.1  General mounting instructions

The installation may only be carried out by authorised 

personnel.

For fitting the AZM 200 AS solenoid interlock, two mounting holes for 

M6 screws with washers (washers included in delivery) are provided. 

The solenoid interlock must not be used as an end stop. Any mounting 

position. The mounting position however must be chosen so that the 

ingress of dirt and soiling in the used opening is avoided. The unused 

actuator opening must be sealed by means of the dust-proof flap 

(included in delivery).

Minimum distance between two devices: 100 mm

Fitting of the actuator

Refer to the mounting instructions manual for the corresponding 

actuator.

The actuator must be permanently fitted to the safety guards 

and protected against displacement by suitable measures 

(tamperproof screws, gluing, drilling of the screw heads). 

Please observe the relevant requirements of the standards 

ISO 12100, ISO 14119 and ISO 14120.

Содержание AZM 200 AS

Страница 1: ...the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions...

Страница 2: ...is a safety switch with an interlock function for process protection The safety function consists of safely switching off the code transfer when the guard system is unlocked or opened and maintaining...

Страница 3: ...rin ciple of isolating the supply of power to the solenoid The safety classification for the release function only applies to devices with monitored interlock function in power to unlock version and w...

Страница 4: ...uts of the AS i safety monitor are enabled when the following conditions are met guard door detected the actuator is inserted AZM 200 BZ ST T AS The safety outputs of the AS i safety monitor are only...

Страница 5: ...cyclically queried by the control system through the AS i master To that effect the 4 input bits with the varying SaW code of a Safety at Work slave are evaluated through an OR operation with 4 inputs...

Страница 6: ...be observed refer to error warning switch off after 30 min 7 Set up and maintenance 7 1 Functional testing The safety function of the safety components must be tested The following conditions must be...

Страница 7: ...2013 Notified body for the prototype test T V Rheinland Industrie Service GmbH Alboinstr 56 12103 Berlin ID n 0035 EC prototype test certificate 01 205 5122 01 15 Person authorised for the compilatio...

Страница 8: ...K A Schmersal GmbH Co KG M ddinghofe 30 42279 Wuppertal Germany Phone 49 202 6474 0 Telefax 49 202 6474 100 E Mail info schmersal com Internet www schmersal com...

Отзывы: