background image

5

AZM 161 AS

Operating instructions
Solenoid interlock

EN

AZM 161 Z ST-AS .A.

 Z-variant, power to lock (magnet-operated locking)

System condition

Magnet input

AS-i D Out: 0

Channel 1

Yellow LED

Channel 2

Yellow LED

SaW code

Authorized operation

AS-i FID

Red LED

Parameter port

P0 - P1 - P2 - P3

Safety guard open

0

---

---

0

0

0

0

---

0

0

1

0

Safety guard closed

0

---

---

0

0

0

0

---

1

0

1

0

Safety guard locked

1

ON

ON

SaW code

---

1

1

1

0

Locking blocked

1

---

---

0

0

0

0

Flashes

1

0

1

1

Unlocking blocked

0

ON

ON

SaW code

Flashes

1

1

1

1

AZM 161 B ST-AS .A. 

 

B-variant, power to lock (magnet-operated locking)

System condition

Magnet input

AS-i D Out: 0

Channel 1

Yellow LED

Channel 2

Yellow LED

SaW code

Authorized operation

AS-i FID

Red LED

Parameter port

P0 - P1 - P2 - P3

Safety guard open

0

---

---

0

0

0

0

---

0

0

1

0

Safety guard closed

0

ON

ON

SaW code

---

1

0

1

0

Safety guard locked

1

ON

ON

SaW code

---

1

1

1

0

Locking blocked

1

ON

ON

SaW code

Flashes

1

0

1

1

Unlocking blocked

0

ON

ON

SaW code

Flashes

1

1

1

1

AZM 161 BZ ST-AS .A. 

 

BZ-variant, power to lock (magnet-operated locking)

System condition

Magnet input

AS-i D Out: 0

Channel 1

Yellow LED

Channel 2

Yellow LED

SaW code

Authorized operation

AS-i FID

Red LED

Parameter port

P0 - P1 - P2 - P3

Safety guard open

0

---

---

0

0

0

0

---

0

0

1

0

Safety guard closed

0

ON

---

HC1 *

0

0

---

1

0

1

0

Safety guard locked

1

ON

ON

SaW code

---

1

1

1

0

Locking blocked

1

ON

---

HC1 *

0

0

Flashes

1

0

1

1

Unlocking blocked

0

ON

ON

SaW code

Flashes

1

1

1

1

HC1

* AS-i half code 1 (AS-i SaW bit 0.1)

AZM 161 Z ST-AS 

 Z-variant, power to unlock (spring-operated locking)

System condition

Magnet input

AS-i D Out: 0

Channel 1

Yellow LED

Channel 2

Yellow LED

SaW code

Authorized operation

AS-i FID

Red LED

Parameter port

P0 - P1 - P2 - P3

Safety guard open

1

---

---

0

0

0

0

---

0

0

1

0

Safety guard closed

1

---

---

0

0

0

0

---

1

0

1

0

Safety guard locked

0

ON

ON

SaW code

---

1

1

1

0

Locking blocked

0

---

---

0

0

0

0

Flashes

1

0

1

1

Unlocking blocked

1

ON

ON

SaW code

Flashes

1

1

1

1

AZM 161 B ST-AS 

 B-variant,power to unlock (spring-operated locking)

System condition

Magnet input

AS-i D Out: 0

Channel 1

Yellow LED

Channel 2

Yellow LED

SaW code

Authorized operation

AS-i FID

Red LED

Parameter port

P0 - P1 - P2 - P3

Safety guard open

1

---

---

0

0

0

0

---

0

0

1

0

Safety guard closed

1

ON

ON

SaW code

---

1

0

1

0

Safety guard locked

0

ON

ON

SaW code

---

1

1

1

0

Locking blocked

0

ON

ON

SaW code

Flashes

1

0

1

1

Unlocking blocked

1

ON

ON

SaW code

Flashes

1

1

1

1

AZM 161 BZ ST-AS  

 BZ-variant, power to unlock (spring-operated locking)

System condition

Magnet input

AS-i D Out: 0

Channel 1

Yellow LED

Channel 2

Yellow LED

SaW code

Authorized operation

AS-i FID

Red LED

Parameter port

P0 - P1 - P2 - P3

Safety guard open

1

---

---

0

0

0

0

---

0

0

1

0

Safety guard closed

1

ON

---

HC1 *

0

0

---

1

0

1

0

Safety guard locked

0

ON

ON

SaW code

---

1

1

1

0

Locking blocked

0

ON

---

HC1 *

0

0

Flashes

1

0

1

1

Unlocking blocked

1

ON

ON

SaW code

Flashes

1

1

1

1

HC1

* AS-i half code 1 (AS-i SaW bit 0.1)

Содержание AZM 161 AS Series

Страница 1: ...t is the responsibility of the manufacturer of a machine or plant to ensure the proper functionality of the entire machinery or plant The safety switchgear must be exclusively used in accordance with...

Страница 2: ...atus can be evaluated through a PLC with AS Inter face master The safety related functions are enabled by means of the AS i safety monitor Interlocks with power to lock principle may only be used in s...

Страница 3: ...100 ED Ambient conditions Ambient temperature 25 C 60 C Storage and transport temperature 25 C 85 C Relative humidity 30 95 no condensation Resistance to vibration 10 150 Hz amplitude 0 35 mm Resistan...

Страница 4: ...endent Suitable for AZM 161 BZ ST AS Independent In 1 As long as the actuator remains inserted the safety guard can be relo cked at any time in which case the safety outputs are reactivated The safety...

Страница 5: ...ng blocked 1 ON HC1 0 0 Flashes 1 0 1 1 Unlocking blocked 0 ON ON SaW code Flashes 1 1 1 1 HC1 AS i half code 1 AS i SaW bit 0 1 AZM 161 Z ST AS Z variant power to unlock spring operated locking Syste...

Страница 6: ...d connections 6 2 Maintenance A regular visual inspection and functional test including the following steps is recommended 1 Check for a secure installation of the actuator and the switch 2 Remove par...

Страница 7: ...n Directives Place and date of issue Wuppertal October 22 2009 Authorised signature Heinz Schmersal Managing Director Name of the safety component AZM 161 AS Description of the safety component Interl...

Страница 8: ...Industrielle Sicherheitsschaltsysteme M ddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Telefon 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet htt...

Отзывы: