5
AZM 161 AS
Operating instructions
Solenoid interlock
EN
AZM 161 Z ST-AS .A.
Z-variant, power to lock (magnet-operated locking)
System condition
Magnet input
AS-i D Out: 0
Channel 1
Yellow LED
Channel 2
Yellow LED
SaW code
Authorized operation
AS-i FID
Red LED
Parameter port
P0 - P1 - P2 - P3
Safety guard open
0
---
---
0
0
0
0
---
0
0
1
0
Safety guard closed
0
---
---
0
0
0
0
---
1
0
1
0
Safety guard locked
1
ON
ON
SaW code
---
1
1
1
0
Locking blocked
1
---
---
0
0
0
0
Flashes
1
0
1
1
Unlocking blocked
0
ON
ON
SaW code
Flashes
1
1
1
1
AZM 161 B ST-AS .A.
B-variant, power to lock (magnet-operated locking)
System condition
Magnet input
AS-i D Out: 0
Channel 1
Yellow LED
Channel 2
Yellow LED
SaW code
Authorized operation
AS-i FID
Red LED
Parameter port
P0 - P1 - P2 - P3
Safety guard open
0
---
---
0
0
0
0
---
0
0
1
0
Safety guard closed
0
ON
ON
SaW code
---
1
0
1
0
Safety guard locked
1
ON
ON
SaW code
---
1
1
1
0
Locking blocked
1
ON
ON
SaW code
Flashes
1
0
1
1
Unlocking blocked
0
ON
ON
SaW code
Flashes
1
1
1
1
AZM 161 BZ ST-AS .A.
BZ-variant, power to lock (magnet-operated locking)
System condition
Magnet input
AS-i D Out: 0
Channel 1
Yellow LED
Channel 2
Yellow LED
SaW code
Authorized operation
AS-i FID
Red LED
Parameter port
P0 - P1 - P2 - P3
Safety guard open
0
---
---
0
0
0
0
---
0
0
1
0
Safety guard closed
0
ON
---
HC1 *
0
0
---
1
0
1
0
Safety guard locked
1
ON
ON
SaW code
---
1
1
1
0
Locking blocked
1
ON
---
HC1 *
0
0
Flashes
1
0
1
1
Unlocking blocked
0
ON
ON
SaW code
Flashes
1
1
1
1
HC1
* AS-i half code 1 (AS-i SaW bit 0.1)
AZM 161 Z ST-AS
Z-variant, power to unlock (spring-operated locking)
System condition
Magnet input
AS-i D Out: 0
Channel 1
Yellow LED
Channel 2
Yellow LED
SaW code
Authorized operation
AS-i FID
Red LED
Parameter port
P0 - P1 - P2 - P3
Safety guard open
1
---
---
0
0
0
0
---
0
0
1
0
Safety guard closed
1
---
---
0
0
0
0
---
1
0
1
0
Safety guard locked
0
ON
ON
SaW code
---
1
1
1
0
Locking blocked
0
---
---
0
0
0
0
Flashes
1
0
1
1
Unlocking blocked
1
ON
ON
SaW code
Flashes
1
1
1
1
AZM 161 B ST-AS
B-variant,power to unlock (spring-operated locking)
System condition
Magnet input
AS-i D Out: 0
Channel 1
Yellow LED
Channel 2
Yellow LED
SaW code
Authorized operation
AS-i FID
Red LED
Parameter port
P0 - P1 - P2 - P3
Safety guard open
1
---
---
0
0
0
0
---
0
0
1
0
Safety guard closed
1
ON
ON
SaW code
---
1
0
1
0
Safety guard locked
0
ON
ON
SaW code
---
1
1
1
0
Locking blocked
0
ON
ON
SaW code
Flashes
1
0
1
1
Unlocking blocked
1
ON
ON
SaW code
Flashes
1
1
1
1
AZM 161 BZ ST-AS
BZ-variant, power to unlock (spring-operated locking)
System condition
Magnet input
AS-i D Out: 0
Channel 1
Yellow LED
Channel 2
Yellow LED
SaW code
Authorized operation
AS-i FID
Red LED
Parameter port
P0 - P1 - P2 - P3
Safety guard open
1
---
---
0
0
0
0
---
0
0
1
0
Safety guard closed
1
ON
---
HC1 *
0
0
---
1
0
1
0
Safety guard locked
0
ON
ON
SaW code
---
1
1
1
0
Locking blocked
0
ON
---
HC1 *
0
0
Flashes
1
0
1
1
Unlocking blocked
1
ON
ON
SaW code
Flashes
1
1
1
1
HC1