3.4 Mounting steps - Outside mounting
Step 1
• Fit actuator onto mounting plate
x
Step 2
• If used, fit lockout tag, fit door handle onto mounting plate MP TG-01
To be observed
• Refer to lockout tag mounting instructions
y
Step 3
• Cut the square bar to size
To be observed
• All measurements in mm
• with emergency handle:
l = s + x + y + 82 + 4*
• without emergency handle: l = s + x + y + 69 + 4*
• Deburr the cut square bar
l
Legend
l
Long square bar
s
Thickness of the door
X
Thickness mounting plate actuator
Y
Thickness of the door handle/emergency handle mounting
plate, if available; take two times "y", if the emergency handle
mounting plate and the door handle mounting plate are installed
4*
only to be observed if a lockout tag is used
Step 4
• Insert square bar into actuator
To be observed
• Door handle must be in horizontal position
• If emergency handle available: observe the orientation of the
square bar for the emergency handle (see drawing)
Step 5
• Mount switch onto mounting plate
• The mounting plate of the switch must be flush-mounted with the
doorpost
To be observed
• Screws: M6
• Thread must be centric to the slotted holes of the mounting plate
1