schmersal AES 1102 Скачать руководство пользователя страница 4

4

Operating instructions

Safety-monitoring module

AES 1102

AES 1112

EN

AES 1102

Monitoring of multiple safety guards in series-parallel circuits by mens 

of magnetic safety sensors

U

24 VDC

YE

GN

GN

GN

YE

YE

PK

GY

GY

GY

PK

PK

BN

WH

WH

WH

BN

BN

e

AES 1102

L1

A1

K1

K3

A2

K2

S14

C

13

S22

S32

14

K4

3

N

M

AES 1112

Monitoring of two safety guards by means of a magnetic safety sensor

AES 1112

L1

A1

K1

K3

14

A2

K4

3

K2

S14

S14

C

C

U

e

S22

S22

S1

S2

S32

S32

13

24 VDC

N

M

BK

BK

BU

BU

BN

BN

WH

WH

Key

A

Positive break

A - C 

S

Non-contact safety sensor

Содержание AES 1102

Страница 1: ...e the correct functionality of the entire machine or plant The safety monitoring module must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in t...

Страница 2: ...iding hinged and removable safety guards AES 1102 Monitoring one safety switch or multiple safety switches in series parallel circuits The number of connected safety switches is restricted by the contract transition resistance and the conduction resistance This overall resistance must not exceed 300 Ω For magnetic safety sensors with LED the brightness of the LED s reduce as the amount of guard do...

Страница 3: ... do not automatically recognise the faults a regular check of the system is recommended The test intervals must be adjusted to the specific application hazard level mechanical and electrical stress If the safety guard is opened the enabling path of the safety monitoring module will open The machine is stopped Inputs AES 1102 C S14 S22 S32 Connect the safety switch with two NC contacts and one NO c...

Страница 4: ...ety sensors U 24VDC YE GN GN GN YE YE PK GY GY GY PK PK BN WH WH WH BN BN e AES1102 L1 A1 K1 K3 A2 K2 S14 C 13 S22 S32 14 K4 3 N M AES 1112 Monitoring of two safety guards by means of a magnetic safety sensor AES1112 L1 A1 K1 K3 14 A2 K4 3 K2 S14 S14 C C Ue S22 S22 S1 S2 S32 S32 13 24VDC N M BK BK BU BU BN BN WH WH Key A Positive break A C S Non contact safety sensor ...

Страница 5: ...es Relevant Directives Machinery Directive EMC Directive RoHS Directive 2006 42 EC 2014 30 EU 2011 65 EU Applied standards DIN EN 60947 5 3 2014 DIN EN ISO 13849 1 2016 DIN EN ISO 13849 2 2013 Notified body for the prototype test DGUV Test Prüf und Zertifizierungsstelle Elektrotechnik Gustav Heinemann Ufer 130 50968 Köln ID n 0340 EC prototype test certificate ET 16118 Person authorised for the co...

Страница 6: ... A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com ...