Schmalz STF 50 Скачать руководство пользователя страница 11

 

 

INSTALLATION AND OPERATION 

30.30.01.01548/00 

www.schmalz.com 

EN   | 11 

3.1.2  Mounting the dust filter 

1.  Prepare the holes in the crane column or wall bracket for attaching the dust filter. 

 

If the product came with a blower console (1.1), there are 
already mounting points for the dust filter. 

2.  Ground the dust filter (see chapter 3.2.1). 
3.  Screw the dust filter onto the mounting bracket (8) using two 

M8 screws. 

4.  Prepare the vacuum hoses for grounding (see chapter 3.2.2). 
5.  Attach and ground the vacuum hoses with the hose clamps 

(see 3.3). 

3.2  Establishing equipotential bonding 

 

 

DANGER

 

 

 

 

Replacing the filter cartridge while vacuum is applied 

 

Risk of injuries 

► 

Before replacing the filter cartridge, ensure that the vacuum generator is 
switched off and that there is no residual vacuum. 

 

 

 

WARNING 

 

 

 

Dispersed dust particles 

 

Damage to eyes and respiratory tract 

► 

Before blowing out the filter cartridge, put on eye protection and a respiratory 
mask. 

 

 

 

WARNING 

 

 

 

Dirt particles in the vacuum supply hose 

 

Risk of explosion 

► 

► 

Ensure that no dirt enters the blower supply hose. 

Ensure that no dust gets inside the filter cartridge during blowing. 

 

 

 

 

WARNING 

 

 

 

Insufficient grounding 

 

Risk of explosion 

► 

Grounding connections must be checked regularly to ensure explosion 
protection. 

 

1.1 

Содержание STF 50

Страница 1: ...www schmalz com Innovative Vacuum for Automation EN Operating Instructions Dust Filter STF for Explosion Protection Zones 30 30 01 01548 00 02 2018...

Страница 2: ...lz GmbH retains the rights established thereby Reproduction of the contents in full or in part is only permitted within the limits of the legal provisions of copyright law Any modifications to or abri...

Страница 3: ...se 7 1 7 Requirements and instructions for installation maintenance and operating staff 8 2 Product Description 9 2 1 Versions 9 3 Installation and Operation 10 3 1 General operating information 10 3...

Страница 4: ...injury if it is not avoided WARNING Type and source of danger Consequence Remedial action Caution This warning informs the user of a risk that could result in injury if it is not avoided CAUTION Type...

Страница 5: ...ing symbol Description General warning symbol Flying debris Electrical voltage Warning of overpressure Floating dust particles Explosive atmosphere 1 3 Mandatory symbols Explanation of the mandatory s...

Страница 6: ...Read the operating instructions thoroughly and keep them for later reference Do not connect the filter or start operations until after you have read and understood the operating instructions fully Us...

Страница 7: ...filter other media or liquids The vacuum must not exceed 500 mbar Overpressure is not permissible The dust filter is classified as follows according to ATEX directive 2014 34 EU II 3G IIB T4 II 3D T13...

Страница 8: ...al and pneumatic principles as well as the appropriate technical terminology To ensure safe operation this work may only be performed by qualified personnel or trained persons working under the superv...

Страница 9: ...on protection zones The model STF 60 is available as a retrofitting kit for older hoist models for explosion protection zones from year of manufacture 5 2017 or later Components Item Designation 1 Air...

Страница 10: ...n Operating temperature between 40 C and 80 C The filter must be watertight Do not draw in warm air The unit must be easily accessible Checks cleaning and replacing the filter cartridge For the tube l...

Страница 11: ...3 3 3 2 Establishing equipotential bonding DANGER Replacing the filter cartridge while vacuum is applied Risk of injuries Before replacing the filter cartridge ensure that the vacuum generator is swit...

Страница 12: ...clips between the filter cartridge and the filter housing 1 Open the filter housing 2 Insert the filter cartridge 6 3 Ensure that the filter cartridge 6 is grounded with the housing using three sprin...

Страница 13: ...icles Damage to eyes and respiratory tract Wear eye protection Wear respiratory protection 1 Open the filter housing 2 Remove the filter cartridge 6 from the housing 3 Replace heavily contaminated or...

Страница 14: ...n Use Part no Legend Filter cartridge Jumbo Dust filter STF EX 10 07 01 00395 W Hose clamp SSB 59 63 STF 50 10 07 10 00096 S Hose clamp SSB 40 60 STF 50 10 07 10 00005 S Hose clamp SSB 60 80 STF 60 10...

Страница 15: ...rating instructions and CAD data and get comprehensive information about our products and services www schmalz com dokumentationen How to videos In short easy to understand videos we explain the exten...

Отзывы: