The three keys on the foil keypad are used for operation and setting the parameters. If no
parameters are set, the ejector is in display mode. The current vacuum is displayed.
If settings are changed, this can cause undefined changes to the system status
for a shot period of time (approx. 50 ms) in certain situations.
V
IEWING AND SETTING PARAMETERS
The following parameters can be set for the ejector:
H1 threshold value for the controller
H2 threshold value for the signal output
Blow-off period for time-controlled blow-off
The hystereses for the threshold values are pre-defined.
LED-bar
H1
h1
H2
h2
Blow-off time
10%
-
-
100 mbar
10 mbar
20 ms
20%
200 mbar
40 mbar
200 mbar
10 mbar
50 ms
30%
300 mbar
60 mbar
300 mbar
10 mbar
100 ms
40%
400 mbar
80 mbar
400 mbar
10 mbar
250 ms
55%
550 mbar
110 mbar
550 mbar
10 mbar
500 ms
65%
650 mbar
130/75 mbar *
650 mbar
10 mbar
750 ms
75%
750 mbar
150/75 mbar*
750 mbar
10 mbar
1000 ms
Max
Control desabled
-
-
1500 ms
*If a value > (H1-h1) is selected for H2, the hysteresis h1 will be dynamically adjusted so
that (H1-h1) is 25 mbar above H2.
The value set for H1 must always be greater than the value set for H2. Only set-
tings that meet this specification can be made.
For H1, the hysteresis is always 20% of the H1 value; the hysteresis h2 is always 10 mbar.
By pressing the
key, you can view the first parameter (threshold value H1). If you press
the
key again, the second parameter (threshold value H2) and the third parameter (blow