INSTALLATION
30.30.01.01117/06
www.schmalz.com
EN | 19
5.1 Electrical Connection
DANGER
Danger of electric shock
This can result in fatal injuries or even death.
►
Before working on electrical components, switch off the main switch and secure
it so that it cannot be switched on again inadvertently.
►
Ensure that the control pendant is suspended by the strain relief device (snap
hook
►
The PE conductor must not carry any operational current. If you are using a
motor-protection switch, you must observe the current strength of the chain
hoist (see the type plate).
Connection 1
Voltage supply from the Schmalz crane system
Connection 2
Voltage supply for a load suspension device
Connection 3
Control pendant / operating panel for VacuMaster Comfort
Power supply:
Connect the flat cable from the Schmalz crane system to connection 1 (Fig. 6).
If you do not have the appropriate plug and cable specifically for your crane system, you can
obtain them from J. Schmalz GmbH (power supply). If required, you can connect the voltage
supply cables of a load suspension device to connection 2. The controller inputs are located at
connection 3.
Table 4: Mains supply pin assignment
Mains connection via flat cable
– chain hoist/load-bearing device
Plug
Cable
Wire designation
1
Brown (1)
L1
2
Black (2)
L2
3
Gray (3)
L3
PE
Green/yellow
PE
Fig. 6
Fig. 7
1
2
3
1
2
3