background image

SAFETY INSTRUCTIONS 

14 |   EN 

www.schmalz.com 

30.30.01.00174/06 

1.9  Emissions 

The vacuum tube lifter 

J

UMBO

 emits noise and hot exhaust air. 

The vacuum generator will atomize and disperse any media that is sucked in. It is therefore important 
that no polluted or contaminated ambient air (particle size max. 5 µm) is sucked in. If the ambient air is 
dusty, a dust filter must be used.  
 

 

 

CAUTION 

 

 

 

Noise pollution from the vacuum generator 

 

Noise pollution can cause hearing damage. 

► 

Wear ear protectors 

 

 

 

 

 

CAUTION 

 

 

 

Hot air flows from the outlet side of the blower, heating up the blower and 
surrounding components 

 

 

This presents a burn hazard 

► 

Keep your distance from the blower! 

► 

Observe a cooling time of 60 minutes before working on the blower. 

 

 

 

CAUTION 

 

 

 

Risk of eye injury 

 

All vacuum generators generate an exhaust air flow. Depending on the purity of 
the ambient air, this exhaust air can contain particles, which escape from the 
exhaust air outlet at high speed, potentially injuring people in the face and eye 
area. 

 

 

 

► 

Do not look into the exhaust air flow. 

► 

Wear protective glasses. 

1.10 Personal protective equipment 

When operating the vacuum tube lifter 

J

UMBO

, always wear suitable protective equipment: 

 

 

Safety shoes (in accordance with EN 20345 safety class S1 or better) 

 

Sturdy work gloves (in accordance with EN 388 safety category 2133 or better) 

 

Industrial safety helmet (in accordance with EN 397) 

 

Protective glasses (class F) 

 

Other protective equipment as required by the situation or prescribed by national regulations. 

 

Содержание Jumbo Flex 20

Страница 1: ...www schmalz com Innovative Vacuum for Automation EN Operating Instructions Jumbo Flex 20 35 50 30 30 01 00174 06 06 2018...

Страница 2: ...ght J Schmalz GmbH retains the rights established thereby Reproduction of the contents in full or in part is only permitted within the limits of the legal provisions of copyright law Any modifications...

Страница 3: ...be 17 2 5 Vacuum Generators 17 2 5 1 Compressed air deactivation when using an ejector 18 2 6 Rotary union 18 2 7 Supply hose compressed air hose 18 2 8 Load bearing devices suction pads 19 2 9 Mechan...

Страница 4: ...depositing loads 37 6 8 1 Lifting loads 38 6 8 2 Lowering and setting down loads 38 6 8 3 Picking up vertically and depositing horizontally 39 6 9 Continuous rotatability 39 6 10 Parking the vacuum tu...

Страница 5: ...SAFETY INSTRUCTIONS 30 30 01 00174 06 www schmalz com EN 5 Online documentation 50 How to videos 50...

Страница 6: ...This warning informs the user of a risk that could result in death or serious injury if it is not avoided WARNING Type and source of danger Consequence Remedial action Caution This warning informs th...

Страница 7: ...ectrical voltage Flying debris Hand injury Crushing injury warning Suspended load Fall hazard Vacuum Hearing damage Falling parts Hot surfaces 1 3 Mandatory symbol Explanation of the mandatory symbols...

Страница 8: ...are persons who have received technical training and have the knowledge and experience including knowledge of corresponding regulations necessary to enable him or her to recognize possible dangers and...

Страница 9: ...lifted have to be rigid to ensure they are not destroyed during lifting The permissible upper load limits are defined in section 3 Technical Data and must not be exceeded For details of the maximum pe...

Страница 10: ...omise the integrity and function of the tube lifter There is a risk that the load or gripper may fall crushing body parts or fatally injuring people in the vicinity Do not make any on site modificatio...

Страница 11: ...ntaining and repairing the crane system at the company only employ insured persons who Are 18 years of age or older physically and mentally capable Have been trained in operating and maintaining the t...

Страница 12: ...temperature range If the tube lifter is used outside of the permitted temperature range it will become damaged and fail Only use the tube lifter at the permitted ambient temperature Before operating o...

Страница 13: ...tube lifter JUMBO will fall or drop quickly or that the gripper will become detached from the load and spring upward In the event that the load falls the danger zone greatly depends on the type of lo...

Страница 14: ...he blower Observe a cooling time of 60 minutes before working on the blower CAUTION Risk of eye injury All vacuum generators generate an exhaust air flow Depending on the purity of the ambient air thi...

Страница 15: ...m Name 1 Vacuum generator depending on equipment 6 Suction pad 2 Suspension eye 7 Ejector 3 Rotary union 8 Pressure reduction valve 4 Lifting unit 9 Pump 5 Operator handle 10 Motor protection switch T...

Страница 16: ...are specified on the type plate This information is important for identifying the device and must always be specified when ordering replacement parts making warranty claims or other inquiries about t...

Страница 17: ...0 35 only 2 4 Lift tube The lift tube transfers the vacuum to the suction pad creating the lifting force for the vacuum tube lifter JUMBO 2 5 Vacuum Generators Two different versions of the vacuum gen...

Страница 18: ...ans of the activation cable attached to the side of the ejector The activation cable is approx 0 9 m in length The two balls located on the activation cable black and red are used to open and close th...

Страница 19: ...erial and like all sealings are subject to wear To prolong the life of the sealing elements make sure the sealings are attached properly and not subjected to lateral loads Check the resistance of foam...

Страница 20: ...formation see the separate operating instructions supplied with the gripper 2 10Accessories 2 10 1 Dust filter STF If no dust filter has been installed the warranty shall become void if the system fai...

Страница 21: ...tion valve is used to set optimum operating pressure for the ejector It also has a shut off valve for switching the customer supplied compressed air off manually The radio remote control SRC can be us...

Страница 22: ...pension 2 10 9 Vacuum regulation valve VRV The Schmalz Blower Box surrounds the vacuum pump and uses sound dampening material to reduce the noise level to approx 65 db A The silencer box SBB also prot...

Страница 23: ...ifting distance 1500 1800 mm Max lift speed 1 m s Ejector vacuum generation SEM100 JU SEM150 JU Pump vacuum generation working vacuum max 600 mbar EVE 25 D EVE 50 D EVE 40 D EVE 80 D EVE 50 D Max lift...

Страница 24: ...tive packaging or in transit must be reported immediately to the carrier and J Schmalz GmbH 4 2 Packaging The packaging material must be disposed of in accordance with country specific laws and guidel...

Страница 25: ...ATTENTION Improper removal of system from the transportation box System damage Do not apply force Observe the instructions for removing the system from the transportation box When unpacking the lift t...

Страница 26: ...ne jib 7 Attach end buffer to end of crane jib 8 Mount vacuum tube lifter JUMBOFLEX with rotary union in the carrier unit and secure using the retaining split pin 9 Connect supply hose to the rotary u...

Страница 27: ...aight line stretches can also be bridged with plastic pipes The total length should not exceed 50 m Long supply hoses reduce the carrying capacity and the dynamics of the tube lifter 5 2 Mounting the...

Страница 28: ...ate of the pump 3 Make sure to install a disconnecting switch and the appropriate fuse ATTENTION Incorrectly connected operating voltage Material damage to the blower Only operate the blower with the...

Страница 29: ...all the ejector as per the diagram JUMBOFLEX 20 35 Retrofitting an electrical pump onto a pneumatic ejector Remove the hose nozzle and the suspension eye on the rotary union Screw the suction side of...

Страница 30: ...ed position using a box cutter cut off the wire spiral using the bolt cutter To facilitate the mounting of the lift tube spread the multipurpose grease on the inside of the operator handle Figure 2 Tw...

Страница 31: ...lifter cannot grip the supporting surface when in its lowest position Minimum clearance 10 cm 5 5 Test Installation of the vacuum tube lifter Jumbo is complete following 3 4 successful test runs usin...

Страница 32: ...understood the operating instructions The operator must not leave the vacuum tube lifter Jumbo when a load is attached Wear ear protectors to prevent hearing damage WARNING Risk of injury due to high...

Страница 33: ...ag or pull them Only pick up and lift suitable loads test their intrinsic stability and porosity The working area must be secured by the user operator The persons equipment necessary to secure this ar...

Страница 34: ...immediately WARNING Risk of injury due to lowering of the tube lifter in the event of a power failure or vacuum generator failure This can result in a crushing injury If the vacuum in the lift tube c...

Страница 35: ...e lift tube may implode The tube lifter must hang freely but must not be able to adhere to any surface It must not be in its storage rack 6 4 1 With electrical vacuum generation 1 Switch the pump moto...

Страница 36: ...e may be hit and could injure themselves Check settings before operation Avoid unintentional adjustments 6 6 Integrated quick change adapter replacing the suction pads CAUTION Risk of injury If the su...

Страница 37: ...2 which has 2 pressure points 1 Lowering the load 2 Releasing removing ejecting the load Pressing the actuating lever 1 towards the device opens the air escape valve and the JUMBO is lowered When the...

Страница 38: ...Move the load to the desired location 2 Slowly press the actuating lever 1 2 and move it into the Lower 1 position The lift tube of the device relaxes and the suction pad lowers together with load 3...

Страница 39: ...e joint Always keep one hand on the operator handle Use the other hand to support the swiveling process position your hand on the side of the workpiece 6 9 Continuous rotatability The vacuum tube lift...

Страница 40: ...e and provides the operator with an overview of the many integrated functions of the JumboFlex tube lifter right at the machine The quick reference guide has been designed in a size that is easy to se...

Страница 41: ...care not to damage the lift tube in any way when doing this The suction pad must be detached and stored separately ATTENTION Suction pad damage Suction pads become deformed age prematurely and fall ou...

Страница 42: ...tained Vacuum tube lifter JUMBO with pump Examine the supply hose and tube lifter for cracks Check gripping mechanism Clean dust filter cartridge and filter of the operator handle for Flex 20 35 and p...

Страница 43: ...ipper Check hose replace if necessary Eliminate interference contours see section 1 7 The load falls when lowering Consult with the manufacturer Consult with the manufacturer Vacuum is attained but th...

Страница 44: ...lt into the rotary union of the vacuum tube lifter JUMBO This prevents the working vacuum from falling too quickly in the event of a power failure Check this non return valve at the start of every shi...

Страница 45: ...rtened in the case of higher loads Interval Daily Weekly Monthly Every six months Annual check Vacuum generation Checking the carbon vane and the integrated filter X If additional filter is present ha...

Страница 46: ...ice be easily raised and lowered when not carrying a vacuum gripped load X X Can the hovering position be set easily when the device is carrying a load by turning the adjusting screw on the operator h...

Страница 47: ...ter at least once a month The filter must be cleaned and maintained regularly to guarantee that the tube lifter operates correctly WARNING Risk of injury from falling workpieces If the filter screen i...

Страница 48: ...at least once a week and clean as necessary e g sack gripper 9 9 Expert approval Please observe the national accident prevention laws and regulations Make sure that inspections and tests are arranged...

Страница 49: ...he lift tube to prevent it from falling then release the catches on the trolley connecting bolts 6 Loosen the trolley connecting bolts and slowly suspend the lift tube 10 2Disposal Only qualified spec...

Страница 50: ...perating instructions and CAD data and get comprehensive information about our products and services www schmalz com dokumentationen How to videos In short easy to understand videos we explain the com...

Отзывы: