Technical Data
30 / 96
EN
· 30.30.01.02851 · 01 · 03/22
Time diagram for FXP-i and FMP-i NC
24V
0V
Time
24V
0V
Time
24V
0V
Time
With the area grippers for external vacuum generators FMP-i, the time that the gripper requires to
deposit a workpiece can be reduced. To do so, the signal for closing the vacuum valve is provided earlier
while the gripper is still moving (orange dotted line). The time is dependent on the installation conditions
for the grippers (guide value: 0.3 to 0.5 seconds).
4.4.8
Pneumatic Circuit for Several Grippers FMP-i
For grippers of type FMP-i, the external vacuum valve (parallel and serial connection) is replaced with the vacuum
valve that is integrated in the gripper.
For the parallel connection of the area grippers FMP, each gripper on the hose connector requires an integrated
vacuum valve (
FMP-i).
For the series connection of the area grippers FMP, only the first gripper (
FMP-i) on the inlet hose connector
requires an integrated vacuum valve; all the others can be designed as FMP grippers.
Legend:
1
2
3
Vacuum generator (blower, pump)
Compressed air source
Vacuum filter
Vacuum distributor
Vacuum area gripping system FMP(-S)