Component Functions
48 / 94
EN-US · 30.30.01.02237 · 00 · 04/20
Value range
-
String #1: Bus module;
Strings #2 – #17: Ejec-
tors;
Strings #18 – #23: IOL
master and DI module
Default value
-
***
-
Unit
-
EEPROM
Yes
–
Offset parame-
ter
247 (0x00F7)
248 (0x00F8)
254 (0x00FE)
Description
GSD web link
NFC web link
System configuration (at
delivery)
Index
-
Data type
char
uint8
Length
64 bytes
Access
Read/write
Read only
Value range
–
See 3.1.1 “Ejector Desig-
nation”
Default value
***
https://myprod-
uct.schmalz.com/#/
–
Unit
-
EEPROM
Yes
6.2.3 User-Specific Localization
The following parameters are available when saving user-specific information:
•
Identification of the installation location
•
Identification of the storage location
•
Equipment labeling from the circuit diagram
•
Installation date
•
Geo-location
The parameters are ASCII character strings with the maximum length given in section 5.3. Parameter data.
They can also be used for other purposes if necessary.
The NFC web link parameter is a special feature. This parameter must include a valid web address begin-
ning with http:// or https:// and is automatically used as a web address for NFC read accesses. As a result,
read accesses from smart phones or tablets are rerouted e.g. to an address in the company's own intranet
or a local server.
Offset parame-
ter
249 (0x00F9)
253 (0x00FD)
247 (0x00F7)
Description
Storage location
Installation date
GSD web link
Index
-
Data type
char
Length
32 bytes
16 bytes
64 bytes
Access
Read/write
Value range
-