9 Help with Faults
EN-US · 30.30.00.00422 · 08 · 09/22
29 / 36
9 Help with Faults
Fault
Cause
Solution
Ejector does not re-
spond
No actuator supply voltage
4
Check electrical connection and pin as-
signment
No compressed air supply
4
Check the compressed air supply.
Ejector is faulty.
4
Check the ejector and contact Schmalz
Service if necessary.
Vacuum level is not
reached or vacuum is
created too slowly
Press-in screen in contami-
nated
4
Replace screen
Silencer is dirty
4
Replace silencer insert
Hose or screw unions are leak-
ing
4
Replace or seal components
Leakage at suction cup
4
Eliminate leakage from suction cup
Operating pressure too low
4
Increase operating pressure, observe
maximum limits
Internal diameter of hose line
too small
4
Observe recommendations for hose di-
ameter
Load cannot be held
Vacuum level too low
1. Increase the control range for the air
saving function
2. Increase operating pressure, observe
maximum limits
Suction cup too small
4
Select a larger suction cup