Operating and Menu Concepts
22 / 52
EN-US · 30.30.01.01963 · 00 · 05/19
3. Use the
button to change the value. The value increases by 1 each time the button is pressed.
After 9, the counter goes back to 0 when the
button is pressed.
4. Press the
button to save the modified value.
ð
The first digit is accepted and the second digit flashes.
5. Use the
button to set the second digit.
6. Press the
button to save the modified value.
ð
The second digit is accepted and the third digit flashes.
7. Use the
button to set the third digit.
8. Press the
button to save the modified value.
ð
The value is accepted and the modified parameter is displayed.
If input is interrupted for longer than 1 minute or if no input is made, the display automatically switches
to the measurement display.
For other parameters, you can select among predefined settings:
1. Use the
button to select the desired parameter.
2. Confirm using the
button.
ð
The current setting is displayed and flashes.
3. Use the
button to switch to the next setting.
4. Press the
button to save the desired setting.
ð
The selected setting is briefly shown on the display.
ð
The display then automatically jumps to the parameter that was just set.
5.4 Info menu [INF]
The “Info” [INF] menu is available for reading out system data such as counters, the software version, part
numbers and serial numbers.
5.4.1 Functions in the Info menu
The following table shows an overview of the display codes and parameters in the Info menu:
Display code
Parameter
Explanation
cc1
Counter 1
Counter for suction cycles (suction signal input)
cc2
Counter 2
Valve switching cycles
5oC
Software
Indicates the software version
Art
Article/part number
The part number is displayed
5nr
Serial number
The serial number is displayed
Information about the production period