8.2 Overview of the Display Codes
Code
Parameter
Note
X-1
Limit value H1
Deactivation value of the control function (only if
ctr
=
on
is active)
5PE
Power
Indicates the percentage of the pump capacity in SIO mode
(only if
ctr
=
off
is active)
X-2
Limit value H2
Activation value of "Parts control" signal output
h-2
Hysteresis value h2
Hysteresis of "Parts control" signal output
tbL
Ventilation time
Ventilation time setting for internal, time-controlled blow off
(only if
blo
=
1-t
or
E-t
is active)
CAL
Zero-point adjust-
ment
Calibrate vacuum sensor, zero point = ambient pressure
ctr
Control
Setting the control function
ctr
=
on
Control function on
ctr
=
off
Control function off, speed control via
5PE
in the basic menu
t-1
Evacuation time
Setting for the maximum permitted evacuation time in ms
bLo
Blow off function
Menu for configuring the blow off function
-E-
"External" ventila-
tion
Selection of externally controlled ventilation
1-t
"Internal" ventilation
Selection of internally controlled ventilation (triggered internally; time can be
set)
E-t
"Externally time-con-
trolled" ventilation
Selection of externally controlled ventilation (triggered externally; time can be
set)
55t
Soft Start
The starting current is limited to approx. 600 mA
o-2
Signal output
Menu for configuring the OUT
2
signal output
o-3
Signal output
Menu for configuring the OUT
3
signal output
no
Normally open con-
tact
Setting of the signal output as a normally open contact
nc
Normally closed con-
tact
Setting of the signal output as a normally closed contact
tyi
Signal type at the in-
put
Menu for configuring the signal type at the input (NPN / PNP)
tyo
Signal type at the
output
Menu for configuring the signal type at the output (NPN / PNP)
PnP
PNP signal type
All input and output signals switch according to PNP (input / output on = 24 V)
nPn
NPN signal type
All input and output signals switch according to NPN (input / output on = 0 V)
uni
Vacuum unit
Setting the vacuum unit
-bA
Vacuum value in
mbar
The displayed values are shown in mbar
-ix
Vacuum value in Hg
The displayed values are shown in inchHg
-PA
Vacuum value in kPa
The displayed values are shown in kPa
P5i
Vacuum value in psi
The displayed values are shown in psi
dLY
Switch-off delay
Switch-off delay setting for OUT
2
; Off, 10, 50 or 200 ms
5td
Default display
Display is not rotated
rot
Display rotation
Display is rotated by 180°
Eco
ECO mode
Setting ECO mode
on
for display switches off
oFF
for display remains on
Lo
for dimmed display
P1n
PIN code
Entry of the PIN code for unlocking the menu
rE5
Reset
All values are reset to the factory settings
Cc1
Counter 1
Counter for suction cycles (suction signal input)
8 / 9
EN-US · 30.30.01.01506 · 01 · 02/18