INSTALLATION
14 | EN
www.schmalz.com
30.30.01.00159/01
5
Installation
Please read section 1.6 (Requirements & instructions for installation,
maintenance and operating staff) before starting installation.
5.1 Mounting with vacuum pump
Tools required:
Allen key, size 5
Wrench in size 10, 25, 32, 36
Alternatively pipe wrench (for size 32 and size 36)
Image
Work step description
1
1. Remove the cover from the
Schmalz Blower Box.
2. Position the base plate at the
intended installation location.
Important:
If the Schmalz Blower Box is
used, the vacuum pump may only be
installed in a horizontal position. The base
plate must be securely connected to the
support with 4 screws.
Exception: The blower does not have to be
secured for floor mounting.
2
Remove the cover from the Schmalz Blower
Box.
3
Drilling template for EVE-TR 25 (1)
Drilling template for EVE-TR 40 / 50 (2)