Description of Functions
24 / 52
EN-US · 30.30.01.01963 · 01 · 09/21
6.4.2 Manual Mode
CAUTION
Changing the output signals in manual mode
Personal injury or damage to property!
4
Electrical connection and manual operation may be performed only by a qualified spe-
cialist who can predict the effects that signal changes will have on the entire system.
In manual mode, the “suction” and “blow off” ejector functions can be controlled independently of the
higher-level controller using the buttons on the foil keypad of the operating element. This function is
used, among other things, to detect and eliminate leakages in the vacuum circuit.
In this operating mode, the “SP1” and “SP2” LEDs both flash.
Activating Manual Mode
CAUTION
External signals may change manual mode
Personal injury or property damage due to unforeseen work steps!
4
There must be no people in the system’s danger area while it is in operation.
ü
The ejector is on the measurement screen.
4
Press and hold the
and
buttons simultaneously for at least 3 seconds.
ð
The “SP1” and “SP2” LEDs flash.
Deactivating Manual Mode
ü
The ejector is in “manual mode”.
4
Briefly press the
and
buttons at the same time.
ð
The SP1 and SP2 LEDs cease to flash.
The device also exits manual mode when the status of the external signals changes.
When the ejector receives an external signal, it switches to automatic mode.
Activating and Deactivating Manual Suction
Activating manual suction
ü
The ejector is in “manual mode”. The SP1 and SP2 LEDs flash.
4
Press the
button to activate “suction” mode.
ð
The suction LED S lights up.
ð
The ejector begins to suck.
Содержание 10.02.02.05588
Страница 1: ...Mini Compact Ejector SCPMc Operating Instructions WWW SCHMALZ COM EN US 30 30 01 01963 01 09 21 ...
Страница 16: ...Technical Data 16 52 EN US 30 30 01 01963 01 09 21 NC NO NC EB NO EB ...
Страница 51: ...30 30 01 01963 01 10 21 51 52 ...
Страница 52: ... J Schmalz GmbH EN US 30 30 01 01963 01 09 21 Subject to technical changes without notice ...