![Schluter Systems DH E BW Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/schluter-systems/dh-e-bw/dh-e-bw_user-manual_1212784012.webp)
Display in degrees Fahrenheit/Celsius
The thermostat can display the ambient temperature and the
set point in degrees Fahrenheit (standard factory setting) or
Celsius.
Adjustment procedure for degrees Fahrenheit/Celsius display:
1. To switch from degrees Fahrenheit to degrees Celsius,
and conversely, the thermostat must be in the Day mode.
If so, simultaneously press down the + and - buttons
for more than 3 seconds until the icon blinks.
2. Press down the + button to switch from degrees Fahrenheit
to degrees Celsius, and conversely. The degree Celsius
or Fahrenheit symbol is displayed.
3. When the adjustment is completed, do not press down any
button for 5 seconds to exit the adjustment function.
/
Mode
To switch from the
mode to the
mode, or conversely,
press down the A
/
F button (when you are not in any
adjustment mode). Then, the temperature set point will
become the same as the
or
mode temperature, as
applicable.
Safe mode
If the thermostat fails to detect the presence of a floor
sensor, it will automatically revert to
mode at a setpoint of
21°C (70°F) (with a maximum set point temperature of
24°C – 75°F).
Sensor selection
If you want to use the DH E RS /BW thermostat of Schluter
®
-
Systems with a temperature sensor already installed in the
floor (other than the sensor supplied with this thermostat), you
must contact Schluter
®
-Systems’ customer service to validate
the compatibility between the sensor and the thermostat. You
must know the serial number and name of the installed sensor.
12