Quick Start Guide | Uni-M Panduit Ferrule Applicator in UniCrimp 200
Edition 1.4P (09-2019)
www.schleuniger-na.com
3
3
CAUTION
Confirm proper ferrule position before initiating a full cycle!
To prevent tooling damage, before initiating a full crimp cycle, verify that the ferrules are in the proper position in the crimp
tooling. If they are not in the proper position, use the jog buttons to open/close the tooling.
a.
If the first ferrule lies to the left of the tooling, continue to cycle the press through until the first ferrule is captured properly in the tooling.
b.
If the ferrules are not captured properly in the tooling, open the tooling using the opposite jog button and try to adjust the strip. If the strip cannot be adjusted
so that the ferrule is properly captured, the feed must be adjusted. Refer to manual.
21.
After verifying that the ferrules will be properly captured, install the funnel unit (11) and ensure it is properly aligned. The tooling must be raised, in
the upper position to install the funnel unit.
22.
Once the funnel unit is properly aligned, you should be ready to begin crimping.
Measuring Crimp Height
The sketch below represents a side view of a crimped ferrule. Crimp height should be measured in a high spot (CH2) and not a low spot (CH1).
Verify/adjust crimp height
1.
Verify crimp height and overall crimp quality.
2.
Reduce crimp height by turning the top dial clockwise (to the left).
3.
Increase crimp height by turning the top dial counterclockwise (to the right).
Remove the ferrule strip
1.
Using the jog buttons, raise the press ram to the top.
2.
Remove air pressure.
3.
Open the shield and clear the ferrule on the anvil if one is present.
4.
Lift the ferrule brake lever (10) and the feed finger.
5.
Gently pull the ferrule strip to the left to remove the strip.
Remove the applicator
1.
Using the jog buttons, raise the press ram to the top.
2.
Remove air pressure.
3.
Open the shield.
4.
Install the red tooling protection ring (4).
5.
Remove the hose fitting (7) from the quick connect on the applicator (8).
6.
Release the base plate lever (1).
7.
Ensure a firm grip on the applicator and remove it to the left.
CAUTION
To prevent tooling damage, always ensure the red protection ring is installed when the
applicator is not in use!
The protection ring prevents the upper tooling from accidentally making contact with the lower tooling. Such
contact may damage or wear tooling prematurely.
CH2
CH1
CH2