Schletter FixZ-15 Скачать руководство пользователя страница 1

EN

1

© Schletter GmbH 

 Gewerbegebiet an der B15 

 Alustraße 1 

 83527 Kirchdorf/Haag i. OB 

 Germany 

 Tel.: +49 8072 9191-200

Fax: +49 8072 9191-9200 

 E-mail: [email protected] 

 www.schletter.eu 

 Updated 08/2012 

 Subject to change without notice

Your  contact  in  the  UK:  Schletter  UK  Limited,  Tel.:  +44  1296  461  800,  Fax:  +44  1296  461  801,  E-mail:  [email protected]

FixZ-7 Mounting Instructions

Safety instructions

FixZ-7

Mounting Instructions

System rail upper

End clamp

Middle clamp

System rail lower

 Planning, mounting and start-up of the solar plant must be performed by quali

fi

 ed personnel only. Poor quality execution can 

result in damage to the plant and to the building and can present a risk to people.

Risk of falling! There is a risk of falling when working on the roof as well as when ascending and descending the building. Accident 
prevention regulations must be observed and appropriate safety equipment must be used.

Risk of injury! Objects falling from the roof can hurt or even kill people. The danger area around the installation site must be sealed 
o

ff

  and people close to this area must be warned. 

Required tools

Screwdriver with bits: 
Bit T40 
Bit hex-head SW6

Corresponding tools
for the selected fasteners

 

The Schletter tool kit comprises 

 

tools required for all standard  

 

 

systems.

Risk of breakage! PV modules can be damaged if stepped upon. 

Risk of electric shock! The mounting and maintenance of the PV modules must be carried out by quali

fi

 ed 

personnel only. Please observe the all safety regulations issued by the manufacturer!

 

Fastener (Fix2000 KlickTop)

Additional documentation

Structural analysis 

Analysis print-out with schematic diagram
from the plant calculation

Содержание FixZ-15

Страница 1: ...when working on the roof as well as when ascending and descending the building Accident prevention regulations must be observed and appropriate safety equipment must be used Risk of injury Objects fal...

Страница 2: ...4 e 10 e 10 e 10 e 10 e 4 e 4 h a b b a o Mount fasteners t Select corresponding distance be tween fasteners a for the respective module The exact dimensions are displayed for you in the Autokalkula t...

Страница 3: ...UK Schletter UK Limited Tel 44 1296 461 800 Fax 44 1296 461 801 E mail info schletter co uk FixZ 7 Mounting Instructions p Mount system rail t Mount system rail on the fasteners in our example Hook i...

Страница 4: ...systems please visit our website www schletter eu under Downloads in the Solar section r Module mounting t Position the first module flush with the end of the rail then observe the inden tation distan...

Страница 5: ...when ascending and descending the building Accident prevention regulations must be observed and appropriate safety equipment must be used Risk of injury Objects falling from the roof can cause injury...

Страница 6: ...one Corner zone Roof center zone Edge zone Edge zone Corner zone Edge zone Corner zone x y e 4 e 4 e 10 e 10 e 10 e 10 e 4 e 4 h a b b a o Mounting the fasteners Select corresponding distance be tween...

Страница 7: ...example Hook in to the KlickTop attachment and secure with a 6 Lobe screw T40 q Extending the lower system rail Position next rail Mount the E connector from below Tighten the pre assembled 6 spanner...

Страница 8: ...s please visit our website www schletter eu under Downloads in the Solar Mounting section a s Mounting the module Position the first module flush with the end of the rail then observe the indentation...

Страница 9: ...as when ascending and descending the building Accident prevention regulations must be observed and appropriate safety equipment must be in place Risk of injury Objects falling from the roof can cause...

Страница 10: ...kalkulator t Further recommendations are offered in the structural analysis for fasteners The number of fasteners required is also dependent upon the properties of the roof please verify details with...

Страница 11: ...act in the UK Schletter UK Limited Tel 44 1296 461 800 Fax 44 1296 461 801 E mail info schletter co uk p Mount module bearing profile t Feed square head screws M10x25 into the lower bearing profile an...

Страница 12: ...schletter eu under Downloads in the Solar section r Position bearing plate t Place bearing plate in required fastening position s Module mounting t Position first module to the end of profile t Secur...

Страница 13: ...lified specialists Poor quality execution can result in damage to the plant and to the building and can present a risk to people Risk of falling There is a risk of falling when working on the roof as...

Страница 14: ...okalkulator t Further recommendations are offered in the structural analysis for fasteners The number of fasteners required is also dependent upon the properties of the roof please verify details with...

Страница 15: ...tact in the UK Schletter UK Limited Tel 44 1296 461 800 Fax 44 1296 461 801 E mail info schletter co uk p Mount module bearing profile t Feed square head screws M10x25 into the lower bearing profile a...

Страница 16: ...are nuts t Feed KlickIn click components into the groove at the required positions t Feed square nuts into the click com ponents and twist through 90 so that the rounded edge is underneath s Position...

Страница 17: ...Your contact in the UK Schletter UK Limited Tel 44 1296 461 800 Fax 44 1296 461 801 E mail info schletter co uk v Module mounting t Guide modules into the clamps For further information relating to o...

Отзывы: