Schlagel EDI CONTROL 7 Скачать руководство пользователя страница 4

SCHLAGEL, INC.

                                                  EDI Distributor Control 7

 

 
 

Page 4 of 4 

ERROR MESSAGES

 

The C7 control continuously monitors the distributor for abnormal behavior and will notify the 
operator when a detectable error occurs. The notification is displayed on Line 2 of the display. 
Optional audible or visual alarms are available. Connected PLCs or other automation equipment 
are also notified of the error. 

 

Error Msg 

Reason 

Cause & Remedy 

DRIVE 

ERROR

 

The control has attempted to 
move the spout but has not 
received any feedback that it 
is moving. If it does not 
receive feedback for 10 
seconds, the control will turn 
off the motor and display this 
error message.  

The spout is jammed, the clutch is 
slipping or the sensor circuit is not 
functioning. 

This is a fatal error. Press 

Enter

 to 

reset  the control. This is almost 
always a mechanical obstruction at 
the distributor. 

POSITIONING 

ERR

 

When the control was 
positioning the spout over a 
duct, it was not able to set it 
to the exact predetermined 
position. 

Something has electrically or 
mechanically disturbed the spout 
position over the duct. 

The alarms are set and operator 
notified. Try accessing this position 
again. Repeated errors indicate 
action is required to repair the 
problem. Check for a loose clutch or 
loose drive chains in the drive 
assembly. 

SPOUT 

MOVED

 

This error message indicates 
that the spout has been 
moved out of position after a 
successful stop. The C7 
Control continuously monitor 
spout position and raise this 
alarm if the spout moves out 
of position.

 

Something has electrically or 
mechanically disturbed the spout 
position over the duct. 

This is a fatal error. Press Enter and 
the control will return to the reset 
screen. Check for a loose clutch or 
loose bolts on the drive wheel or 
drive arm assemblies.

 

SENSOR 

ERROR

 

While the control is moving 
the spout it continuously 
anticipates the next code it 
will encounter. If the next 
code does not match the 
anticipated code, the control 
will attempt to re-read it up to 
3 times. If it fails on the 3rd 
try, the control will issue this 
error. 

An improperly positioned sensor 
block in the distributor usually 
causes this error. 

This is a fatal error. Press Enter and 
the control will return to the reset 
screen. Position and shim the sensor 
block properly. Run the Check 
Sensors routine. 

 

Отзывы: