5
6
Verify and Prepare Camera Mounting Location
! Installation in a covered area is recommended.
! Consult the NEC and local electrical codes for information
on electrical requirements.
a. Attach the base to the wall with three (3) screws and
wall anchors (included).
b. Attach the power cable to AC power outlet.
Make sure
the water seal is secure on the wall
.
Attach Camera to Stand
Turn Camera clockwise to attach threaded mount on back of
camera to the swivel connector.
Base
Wall anchors (3)
7
Test the camera view using your Nexia Account.
If necessary, loosen the knob on the swivel connector and adjust the camera angle.
Product Specifications
Lens: Board Mount Type, Fixed-Focal, Aperture F2.0
Night Vision: IR LED x 8, Light Sensor x 1, Auto IR CUT Switcher, Range: Above 5 meters
Minimum Illumination: 0 Lux (with IR LED)
Connectors: RJ45 for Ethernet, DC Power Jack
Power Consumption: 12V DC, Max 4.8W
Compliance: CE, FCC, Power supply: UL
Dimensions (H x W x D): 103 x 94 x 37 mm (4.1” x 3.7” x 1.5”)
Weight: 900g (2 lbs)
Operating Temperature: -10°–45°C (14°–113°F); Humidity: 10%–80% (non-condensing)
Storage Temperature: -20°–70°C (-4°–158°F); Humidity: 10%–90% (non-condensing)
Ethernet: 10/100 Base-T, Auto MDIX
Wireless: IEEE802.11b/g/n, WEP64/128 bit, WPA/WPA2 Personal, WPS
FCC Statement
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications to this equipment not expressly approved by the Schlage Lock Company could void the user’s authority to operate the
equipment. FCC ID: P2GBE369 IC: 7654A-BE369
U.S.A. /Canada
nexiahome.com
(877) 288-7707
© 2012 Ingersoll Rand
Printed in China
24129744 Rev. 05/12-a