Install the Sensor and Magnet

 

! The Sensor and Magnet may be installed using either adhesive tape or screws.
  Follow steps for the preferred method.

 

! For door applications, determine door handing before installation (see examples
 shown 

below).

Install the Sensor with screws

a. 

Use the two fl at-head screws to attach the Sensor mounting bracket to the door jamb or 
window frame.

b. 

Attach the Sensor to the mounting bracket, then push down (or up) to secure the Sensor on 
the bracket.

OR Install the Sensor with adhesive tape

a. 

Attach the Sensor mounting bracket to the door jamb or window frame using a strip of 
double-sided adhesive tape.

b. 

Attach the Sensor to the mounting bracket, then push down (or up) to secure the Sensor on 
the bracket. 

Note: Extended use of double-sided tape may damage paint or wallboard.

Left hand door

OR

Right hand door

OR

 

! The top of the magnet must be within 

¹⁄₄

” (6 mm) of the arrow on the

  Sensor (as shown above).

 

! Install the magnet no more than 

³⁄₄

” (19 mm) away from the Sensor for optimal performance.

Install the Magnet with screws

a. 

Remove the base from the magnet.

b. 

Use two small screws to attach the base of the magnet to the door or window.

c. 

Press the magnet onto the base. 

OR Install the Magnet with adhesive tape

a. 

Attach the magnet to the door or window using a strip of double-sided tape. 

Note: Extended use 

of double-sided tape may damage paint or wallboard.

IMPORTANT!
Sensor and magnet must 
be aligned as shown

¹⁄₄

” (6 mm)

maximum

Arrow

Tabs point 

down

Tabs 

point up

OR

6

Sensor Operation

The Sensor detects and sends open/closed position status to the Nexia Portal. The Sensor is not intended to operate as a 
Z-Wave repeater.

Activity

Sensor LED

Sensor unenrolled

Continuous blinking

Enrollment completed

Solid light

Tamper

Solid light

Open or closed detection

Single blink

Содержание NXRS100HC

Страница 1: ...de The Sensor s LED will blink If the plastic tab is already removed then remove the battery for 10 seconds and replace the battery to restart enrollment mode Battery removal process shown below c The orange LED on the Bridge will blink rapidly when enrollment begins The Bridge and Sensor LEDs will light solid to indicate successful enrollment If the Bridge LED never blinks rapidly and enrollment ...

Страница 2: ...or the browser to refresh LIGHTING MODULES CAMERAS CLIMATE SECURITY SENSORS CLOSED Setup Device New Sensor 3 Sensors Locks Security Sensors New Sensor Sensor Type Door Alerts Alert when opened Alert when closed Save Changes Cancel s s C CLOSED OPEN Sensors Locks my sensor Sensors Locks my sensor CLOSED OPEN Sensors Locks my sensor Sensors Locks my sensor Figure 1 Figure 2 Figure 3 Door Sensor Wind...

Страница 3: ... wallboard Left hand door OR Right hand door OR The top of the magnet must be within 6 mm of the arrow on the Sensor as shown above Install the magnet no more than 19 mm away from the Sensor for optimal performance Install the Magnet with screws a Remove the base from the magnet b Use two small screws to attach the base of the magnet to the door or window c Press the magnet onto the base OR Instal...

Страница 4: ... Press and release the button on the Bridge d Remove the battery from the Sensor e Leave the battery out for at least ten 10 seconds f Reinstall the battery into the Sensor g Observe lights on the Bridge The orange LED will blink rapidly while exclusion is taking place Exclusion is complete when the orange LED lights solid h Remove the battery from the Sensor after exclusion is complete For more i...

Отзывы: