7
14. Locate the cable that runs from the top panel circuit board to the main circuit board. Connect this cable to J9 on the main circuit board.
See figure 10 for cable routing.
15. If not already removed, remove the J7 jumper from the main PCB. See figure 9 below.
J7
Out
J7
In
Figure 9
CAUTION:
If there is a ground strap on the main board, do not allow the ground strap to touch the J7 jumper. Failure to do so will
cause permanent damage to the main circuit board and will not be considered a warranty repair.