E X P L O S I O N P R O O F

!

!

RedMax-  8 -...F1

  ►

RedMax- 15  -

...

F1

 

  8 Nm

15 Nm

 ▼

 3 

s/90° 

  15  s/90° 

 

30  s/90°

 

  60  s/90° 

  120  s/90° 

00

01

02

03

04

05

06

07

08

09

RedBox

S

T

U

o

  =  10,6 V

 I

o

  =  11 mA

P

o

  =  30 mW

C

i

  =  0

 L

i

   =  0

 IIC IIB IIA

L

o

    2 mH  5 mH  10 mH

C

o

  830 nF  3,7 

μ

F   4,5 

μ

F

a

a

a

+

~

+

~

+

~

+

~

~

~

~

~

PE

PE

PE

PE

1

1

1

1

2

2

2

2

3

3

3

3

PA

PA

PA

PA

4

1

7

4

5

2

6

3

8

5

9

6

< 5°

< 5°

> 85°

> 85°

1

2

°C

ExPro-TT

 

 

U < 90 V AC/DC  2 AT  10 AT

U > 90 V AC/DC  5 AT  10 AT

 

 

U < 90 V AC/DC  2 AT  10 AT

U > 90 V AC/DC  5 AT  10 AT

www.schischek.com

Schischek GmbH

 Germany, Muehlsteig 45, Gewerbegebiet Sued 5, 90579 Langenzenn, Tel. +49 9101 9081-0, Fax +49 9101 9081-77, E-Mail [email protected]

RedMax-S-F1_en

V01 –  29-Jun-2017

RedMax-...-F1  RedMax-...-SF1 RedMax-...-BF1
Special options 

... -CTS 

... -VAS

Electrical connection

Parameters, adjustments and failure indication

Parameter selection

Functions, adjustments and parameters

Type

Running times

Position of switch S

Torques

Example: 

RedMax-15-BF1

Requested parameter: 

Torque 

15 Nm

Motor running time  30 s/90°

Result:

Switch position  

02

Installation

Ex area – 

zone 2, 22

Safe area

Supply * 

24...240 VAC/DC ± 10 %

* electrical wiring see diagrams

Switch – Push button – Lamp 

for adjustment 

(behind the blanking plug)

10-position switch (S)
Push button (T)
3-colour LED

All actuators are equipped with a universal supply unit working at a voltage range from 

24...240 VAC/DC. The supply unit is self adjusting to the connected voltage! 

The safety operation of the spring return function works if the supply voltage is cut or line 3 

opened. For electrical connection inside hazardous areas a terminal box is required (e.g. 

RedBox). 

An over-current protection fuse < 10 A has to be provided by installer. 

Note: the initial current is appr. 2 A for 1 second.

Integrated auxiliary switches signal the rotation angle’s position. U

min

 and I

min

 change once 

the switches were operated with higher voltage or current.

Ex-i intrinsic safe data – for temperature trigger ExPro-TT  T 1.0

Attention

During commissioning apply a self adjustment drive. 

Regard duty cycle at motor running times!

Never use spring return actuators without external load.

Auxiliary switches * 

see Technical data

On-off  

SB 2.4

On-off  (1 wire) 

SB 2.5

Wiring of integrated auxiliary switches 

SB 3.2

On-off  – spring Ex-i tripping circuit 

SB 7.4

Ex-i tripping circuit for 

ExPro-TT-... safety 

temperature trigger 

Test 

button

Attention!

At 1-wire control 

mode the heater 

does not work in 

case of open contact. 

24...240 VAC/DC

24...240 VAC/DC

24...240 VAC/DC

24...240 VAC/DC

(?) Switch settings in 

actuator’s normal position.

Integrated auxiliary switches, 

Grid fuse-protection recommended. 

 

min. max.

Integrated auxiliary switches, 

Grid fuse-protection recommended. 

 

min. max.

A)  Self adjustment of angle of rotation 

ATTENTION:

 To adjust the angle of rotation connect only wire 1 and 2. 

Do not connect wire 3. 

Apply supply voltage to wire 1 and 2. Turn switch (S) to position 02. Press 

button (T) for a minimum of 3 seconds. The actuator drives to the first end position, 

detects the blocking position and performs a spring return to the starting position. 

The LED flashes GREEN during adjustment. After that disconnect from the mains 

and connect wire 3. 

The adjustment takes about 31 seconds (30 sec. “On”, 1 sec. “Off”).

B)  Selecting motor running time 

Adjust parameters only if actuator is in idle state or without applied potential. 

Turn switch (S) to the position required for the intended operation acc. to table 

above. The selected parameters will be carried out at the actuator’s next operation.  

C)  Function of the ExPro-TT-... in the Ex-i tripping circuit 

When the ...Pro-TT’s tripping circuit is opened the actuator runs into its end position 

with spring return.

D)  Additional information for control in On-off operation 

a closed  

= actuator opens

a open  

= spring return

The rotation direction (clockwise/counter clockwise) depends on left/right 

mounting of the actuator to the damper. 

3 / 4

Содержание RedMax-8-F1

Страница 1: ...pharmaceutical industrial and offshore onshore plants for use in Ex areas zone 2 gas and zone 22 dust Highest protection class ATEX and IP66 protection small dimensions only 3 5 kg weight universal functions and technical data an integrated heater and an optional stainless steel housing guarantee safe operation even under difficult environmental conditions High quality brushless motors guarantee l...

Страница 2: ...100 mA Umin AC DC 12 V Umax Imax DC 48 V 1 A Imin AC DC 5 mA Imin AC DC 100 mA Axle of the actuator Double square 12 12 mm direct coupling 100 overload protected Electrical connection Cable 1 m wire cross section 0 5 mm equipotential bonding 4 mm Connections in hazardous areas require a terminal box Diameter of cable Ø 6 2 mm Ø 6 2 mm Ø 6 2 7 4 mm Ø 9 3 mm 2 cable glands in version SF1 Cable gland...

Страница 3: ...tage or current Ex i intrinsic safe data for temperature trigger ExPro TT T 1 0 Attention During commissioning apply a self adjustment drive Regard duty cycle at motor running times Never use spring return actuators without external load Auxiliary switches see Technical data On off SB 2 4 On off 1 wire SB 2 5 Wiring of integrated auxiliary switches SB 3 2 On off spring return Ex i tripping circuit...

Страница 4: ...tion will be blocked for the rest of the idle period Later the release for the next cycle is made automatically by an internal timing relay 4 Same function is applied on spring return actuators fail safe operation is regarded same as a motor running cycle 5 Trying to use the 1 wire On off methode in switch position 0 and 5 software changes the motor running time temporarily and automatically to 15...

Отзывы: