28
XRZ PRO RS
MAINTENANCE
AIR CLEANER
Clean and replace the air cleaner element as speci-
fied in the service chart. Uneven running, lack of
power or black exhaust may indicate a dirty air
cleaner.
1. Unclamp end cover
C
and remove existing
cleaner element
A
.
2. Insert new element A and replace cover
C
.
Ensure breathing port
B
is pointing down and
towards the front of the tractor.
ENGINE COOLING
Continued operation with a clogged cooling system
will cause severe overheating and can result in en-
gine damage.
-
Daily
: Clean air intake screen
V
.
-
Every 100 hours
: Clean cooling fins beneath
blower housing
H
with reference to information in
the engine manufacturer's manual.